fsX25NEWL3DefEntry OBJECT-TYPE SYNTAX FsX25NEWL3DefEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { fsX25NEWL3PortNo } ::= { fsX25NEWL3DefTable 1 }
fsX25NEWL3DefEntry OBJECT-TYPE SYNTAX FsX25NEWL3DefEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { fsX25NEWL3PortNo } ::= { fsX25NEWL3DefTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.635.1.2.1.10.21.3.1.1 | fsX25NEWL3PortNo | 0 | 0 | None |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.2 | fsX25NEWL3Mode | 0 | 0 | Identifies DCE/DTE mode in which the interface operates. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.3 | fsX25NEWL3TxPacketSize | 0 | 0 | The transmit packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.4 | fsX25NEWL3RxPacketSize | 0 | 0 | The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be r… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.5 | fsX25NEWL3Sequencing | 0 | 0 | The modulus of the packet sequence number space. The default value is 'modulo8'. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.6 | fsX25NEWL3TxWindowSize | 0 | 0 | The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be r… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.7 | fsX25NEWL3RxWindowSize | 0 | 0 | The receive window size for a circuit. If this parameter is changed and if there are any active VCs, the particular port will be … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.8 | fsX25NEWL3RestartTimer | 0 | 0 | The T20 restart timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.9 | fsX25NEWL3CallTimer | 0 | 0 | The T21 Call timer in seconds. The default value is 200. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.10 | fsX25NEWL3ResetTimer | 0 | 0 | The T22 Reset timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.11 | fsX25NEWL3ClearTimer | 0 | 0 | The T23 Clear timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.12 | fsX25NEWL3InputCallFacOpt | 0 | 0 | This field controls the manner in which this port will respond when presented with any input Call Packet containing faciliities t… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.13 | fsX25NEWL3OutputCallFacOpt | 0 | 0 | This field controls the manner in which this port will respond when presented with any output Call Packet containing faciliities … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.14 | fsX25NEWL3HPVC | 0 | 0 | Lowest Incoming channel. The default value is 0. The valid values range from 0 to 4095. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.15 | fsX25NEWL3LSVC | 0 | 0 | Highest Incoming channel. A value of zero indicates no channels in this range. The default value is 0. The valid values range from… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.16 | fsX25NEWL3HSVC | 0 | 0 | Lowest Two-way channel. The default value is 1. The valid values range from 1 to 4095. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.17 | fsX25NEWL3MaxActiveVC | 0 | 0 | Maximum Active VCs at a time. The default value is 20. The valid values range from 0 to 100. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.18 | fsX25NEWL3Status | 0 | 0 | None |