This field controls the manner in which this port
will respond when presented with any input Call
Packet containing faciliities that are not actively
supported by the system.
Regardless of the value of this object, the
system will always clear calls containing
Flow Control Parameter Negotiation facilities
and will handle Reverse Charging facilities as
configured by the operator.
The value of this object will have no effect on
system-generated call processing; any facility
present in calls received by multiprotocol switching
applications will always be ignored.
If this object is set to 'pass-facilities-through',
which is the default, unsupported facilities
will be passed unchanged through the system.
If this object is set to 'remove-facilities',
unsupported facilities will be stripped from
the packet before it is passed on through the
system.
If this object is set to 'clear-call', calls
using unsupported facilities will be cleared
by the system with the Invalid Facility Clear
Cause and Diagnostic Code combination.
Parsed from file FC_PORT.MIB.txt
Company: None
Module: FC-PORT-MIB
This field controls the manner in which this port
will respond when presented with any input Call
Packet containing faciliities that are not actively
supported by the system.
Regardless of the value of this object, the
system will always clear calls containing
Flow Control Parameter Negotiation facilities
and will handle Reverse Charging facilities as
configured by the operator.
The value of this object will have no effect on
system-generated call processing; any facility
present in calls received by multiprotocol switching
applications will always be ignored.
If this object is set to 'pass-facilities-through',
which is the default, unsupported facilities
will be passed unchanged through the system.
If this object is set to 'remove-facilities',
unsupported facilities will be stripped from
the packet before it is passed on through the
system.
If this object is set to 'clear-call', calls
using unsupported facilities will be cleared
by the system with the Invalid Facility Clear
Cause and Diagnostic Code combination.
Parsed from file FC-PORT-MIB.mib
Module: FC-PORT-MIB
Vendor: Encore Networks, Inc.
Module: FC-PORT-MIB
[Automatically extracted from oidview.com]
fsX25NEWL3InputCallFacOpt OBJECT-TYPE SYNTAX INTEGER { pass-facilities-through (1), remove-facilities (2), clear-call (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This field controls the manner in which this port will respond when presented with any input Call Packet containing faciliities that are not actively supported by the system. Regardless of the value of this object, the system will always clear calls containing Flow Control Parameter Negotiation facilities and will handle Reverse Charging facilities as configured by the operator. The value of this object will have no effect on system-generated call processing; any facility present in calls received by multiprotocol switching applications will always be ignored. If this object is set to 'pass-facilities-through', which is the default, unsupported facilities will be passed unchanged through the system. If this object is set to 'remove-facilities', unsupported facilities will be stripped from the packet before it is passed on through the system. If this object is set to 'clear-call', calls using unsupported facilities will be cleared by the system with the Invalid Facility Clear Cause and Diagnostic Code combination." ::= { fsX25NEWL3DefEntry 12 }
fsX25NEWL3InputCallFacOpt OBJECT-TYPE SYNTAX INTEGER { pass-facilities-through (1), remove-facilities (2), clear-call (3) } ACCESS read-write STATUS mandatory DESCRIPTION " This field controls the manner in which this port will respond when presented with any input Call Packet containing faciliities that are not actively supported by the system. Regardless of the value of this object, the system will always clear calls containing Flow Control Parameter Negotiation facilities and will handle Reverse Charging facilities as configured by the operator. The value of this object will have no effect on system-generated call processing; any facility present in calls received by multiprotocol switching applications will always be ignored. If this object is set to 'pass-facilities-through', which is the default, unsupported facilities will be passed unchanged through the system. If this object is set to 'remove-facilities', unsupported facilities will be stripped from the packet before it is passed on through the system. If this object is set to 'clear-call', calls using unsupported facilities will be cleared by the system with the Invalid Facility Clear Cause and Diagnostic Code combination." ::= { fsX25NEWL3DefEntry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.635.1.2.1.10.21.3.1.1 | fsX25NEWL3PortNo | 0 | 0 | None |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.2 | fsX25NEWL3Mode | 0 | 0 | Identifies DCE/DTE mode in which the interface operates. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.3 | fsX25NEWL3TxPacketSize | 0 | 0 | The transmit packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.4 | fsX25NEWL3RxPacketSize | 0 | 0 | The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be r… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.5 | fsX25NEWL3Sequencing | 0 | 0 | The modulus of the packet sequence number space. The default value is 'modulo8'. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.6 | fsX25NEWL3TxWindowSize | 0 | 0 | The receive packet size in octets for a circuit. If this parameter is changed and if there are any active VCs, the port will be r… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.7 | fsX25NEWL3RxWindowSize | 0 | 0 | The receive window size for a circuit. If this parameter is changed and if there are any active VCs, the particular port will be … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.8 | fsX25NEWL3RestartTimer | 0 | 0 | The T20 restart timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.9 | fsX25NEWL3CallTimer | 0 | 0 | The T21 Call timer in seconds. The default value is 200. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.10 | fsX25NEWL3ResetTimer | 0 | 0 | The T22 Reset timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.11 | fsX25NEWL3ClearTimer | 0 | 0 | The T23 Clear timer in seconds. The default value is 180. The valid values range from 10 to 600. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.13 | fsX25NEWL3OutputCallFacOpt | 0 | 0 | This field controls the manner in which this port will respond when presented with any output Call Packet containing faciliities … |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.14 | fsX25NEWL3HPVC | 0 | 0 | Lowest Incoming channel. The default value is 0. The valid values range from 0 to 4095. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.15 | fsX25NEWL3LSVC | 0 | 0 | Highest Incoming channel. A value of zero indicates no channels in this range. The default value is 0. The valid values range from… |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.16 | fsX25NEWL3HSVC | 0 | 0 | Lowest Two-way channel. The default value is 1. The valid values range from 1 to 4095. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.17 | fsX25NEWL3MaxActiveVC | 0 | 0 | Maximum Active VCs at a time. The default value is 20. The valid values range from 0 to 100. |
1.3.6.1.4.1.635.1.2.1.10.21.3.1.18 | fsX25NEWL3Status | 0 | 0 | None |