This counter is incremented when the PSE state diagram
enters the state SIGNATURE_INVALID.
Parsed from file rfc3621-Power-Ethernet.mib.txt
Company: None
Module: POWER-ETHERNET-MIB
Counts the number of times that the
pethPsePortPowerMaintenanceStatus attribute changes from any
value to the value mPSAbsent(3).
Parsed from file POWER-ETHERNET-MIB.mib
Module: POWER-ETHERNET-MIB
Vendor: Alcatel
Module: POWER-ETHERNET-MIB (IETF_HUBMIB_POWER_ETHERNET_DRAFT.mib)
Type: TABULAR
Access: read-only
Syntax: Counter32
Automatically extracted from www.mibdepot.com
pethPsePortInvalidSignatureCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.7 aPSEInvalidSignatureCounter" ::= { pethPsePortEntry 11 }
pethPsePortMPSAbsentCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of times that the pethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3)." REFERENCE "[IEEE Draft P802.3af/D4.0, November, 2002, object 30.9.1.1.9 aPSEUnderCurrentCounter]" ::= { pethPsePortEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.1 | pethPsePortGroupIndex | 0 | 0 | This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in th… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.2 | pethPsePortIndex | 0 | 0 | This variable uniquely identifies the power Ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entr… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.3 | pethPsePortAdminEnable | 0 | 0 | true (1) An interface which can provide the PSE functions. false(2) The interface will act as it would if it had no PSE function. |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.4 | pethPsePortPowerPairsControlAbility | 0 | 0 | Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate … |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.5 | pethPsePortPowerPairs | 0 | 0 | Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of … |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.6 | pethPsePortPowerDetectionControl | 0 | 0 | Controls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. S… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.7 | pethPsePortDetectionStatus | 0 | 0 | Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.8 | pethPsePortPowerPriority | 0 | 0 | This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.10 | pethPsePortPowerMaintenanceStatus | 0 | 0 | The value ok(1) indicates the Power Maintenance Signature is present and the overcurrent condition has not been detected. The valu… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.12 | pethPsePortOverCurrentCounter, pethPsePortPowerDeniedCounter | 0 | 0 | Counts the number of times that the aPSEPowerCurrentStatus attribute changes from any value to the value overCurrent(2). |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.13 | pethPsePortType, pethPsePortOverLoadCounter | 0 | 0 | A manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This… |
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.14 | pethPsePortPowerClassifications, pethPsePortShortCounter | 0 | 0 | Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices su… |