The actual value of the battery recharge level that will be
reached during the time delay necessary to restart after power
returns. This value is computed from upsConfigRechargeTime
(the delay), upsBatteryLevel (the actual level) and the UPS
charge rate.
Parsed from file mg-ups.mib.txt
Company: None
Module: MG-SNMP-UPS-MIB
The actual value of the battery recharge level that will be
reached during the time delay necessary to restart after power
returns. This value is computed from upsmgConfigRechargeTime
(the delay), upsmgBatteryLevel (the actual level) and the UPS
charge rate.
Parsed from file MG-SNMP-UPS-MIB.mib
Module: MG-SNMP-UPS-MIB
Vendor: Merlin Gerin
Module: MG-SNMP-UPS-MIB
[Automatically extracted from oidview.com]
upsBatteryRechargeLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power returns. This value is computed from upsConfigRechargeTime (the delay), upsBatteryLevel (the actual level) and the UPS charge rate." ::= { upsBattery 4 }
upsmgBatteryRechargeLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power returns. This value is computed from upsmgConfigRechargeTime (the delay), upsmgBatteryLevel (the actual level) and the UPS charge rate." ::= { upsmgBattery 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.705.1.5.4.0 | upsBatteryRechargeLevel | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.705.1.5.1 | upsmgBatteryRemainingTime, upsBatteryRemainingTime | 1 | 1 | The time remaining actual charge vs actual load (dynamic). |
1.3.6.1.4.1.705.1.5.2 | upsmgBatteryLevel, upsBatteryLevel | 1 | 1 | The battery level as a percentage of charge. |
1.3.6.1.4.1.705.1.5.3 | upsmgBatteryRechargeTime, upsBatteryRechargeTime | 1 | 1 | The actual operational battery recharge time to set point equal to upsConfigRechargeLevel. This value is computed from upsConfigR… |
1.3.6.1.4.1.705.1.5.5 | upsmgBatteryVoltage, upsBatteryVoltage | 1 | 1 | The actual battery voltage. |
1.3.6.1.4.1.705.1.5.6 | upsmgBatteryCurrent, upsBatteryCurrent | 1 | 1 | The actual battery current. |
1.3.6.1.4.1.705.1.5.7 | upsmgBatteryTemperature, upsBatteryTemperature | 1 | 1 | The battery temperature. |
1.3.6.1.4.1.705.1.5.8 | upsmgBatteryFullRechargeTime, upsBatteryFullRechargeTime | 1 | 1 | The battery full recharge time (from 0 to 100 percent) at current load. |
1.3.6.1.4.1.705.1.5.9 | upsmgBatteryFaultBattery, upsBatteryFaultBattery | 1 | 1 | The battery fault status. |
1.3.6.1.4.1.705.1.5.10 | upsmgBatteryNoBattery, upsBatteryNoBattery | 1 | 1 | The UPS has no Battery status. |
1.3.6.1.4.1.705.1.5.11 | upsmgBatteryReplacement, upsBatteryReplacement | 1 | 1 | The UPS Battery to be replaced status. |
1.3.6.1.4.1.705.1.5.12 | upsmgBatteryUnavailableBattery, upsBatteryUnavailableBattery | 1 | 1 | The UPS Battery is unavailable status. |
1.3.6.1.4.1.705.1.5.13 | upsmgBatteryNotHighCharge, upsBatteryNotHighCharge | 1 | 1 | The UPS Battery quit high condition status. |
1.3.6.1.4.1.705.1.5.14 | upsmgBatteryLowBattery, upsBatteryLowBattery | 1 | 1 | The battery low status. |
1.3.6.1.4.1.705.1.5.15 | upsmgBatteryChargerFault, upsBatteryChargerFault | 1 | 1 | The UPS Battery is not charging status. |
1.3.6.1.4.1.705.1.5.16 | upsmgBatteryLowCondition, upsBatteryLowCondition | 1 | 1 | The UPS is at low condition status. |
1.3.6.1.4.1.705.1.5.17 | upsmgBatteryLowRecharge, upsBatteryLowRecharge | 1 | 1 | The UPS Battery is not recharged status. |