Volume is being restricted. The string sent with trap
specifies name of affected volume and reason for being
restricted.
Parsed from file netapp_2_2_2.mib.txt
Company: None
Module: NETAPP-MIB
Volume is being restricted. The string sent with trap
specifies name of affected volume and reason for being
restricted.
Parsed from file NETWORK-APPLIANCE-MIB.mib
Module: NETWORK-APPLIANCE-MIB
Vendor: Network Appliance Corporation
Module: NETWORK-APPLIANCE-MIB
[Automatically extracted from oidview.com]
volumeRestricted NOTIFICATION-TYPE OBJECTS {productTrapData, productSerialNum} STATUS current DESCRIPTION "Volume is being restricted. The string sent with trap specifies name of affected volume and reason for being restricted." ::= { netapp 0 334 }
volumeRestricted NOTIFICATION-TYPE OBJECTS {productTrapData, productSerialNum} STATUS current DESCRIPTION "Volume is being restricted. The string sent with trap specifies name of affected volume and reason for being restricted." ::= { netapp 0 334 }
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.789.0.284 | rmcCardMissingCables | 0 | 0 | Remote Management Controller card is missing its internal cable, or LAN cable or power supply cable. The trap includes a string s… |
1.3.6.1.4.1.789.0.294 | volumeRemoteUnreachable | 0 | 0 | Local volume encountered an error while communicating to remote volume. |
1.3.6.1.4.1.789.0.296 | volumeRemoteOk | 0 | 0 | The communication between remote volume and local volume returned to normal. |
1.3.6.1.4.1.789.0.297 | volumeRemoteRestored | 0 | 0 | The data on remote volume has been fully restored to local volume. |
1.3.6.1.4.1.789.0.298 | volumeRemoteRestoreBegin | 0 | 0 | The data on remote volume has started being restored to local volume by Restore-on-Demand. |
1.3.6.1.4.1.789.0.304 | volumeRestrictedRootConflict | 0 | 0 | Volume is restricted due to a root volume conflict. The string sent with trap specifies name of conflicting volume which is being… |
1.3.6.1.4.1.789.0.314 | volumeOfflineTooBig | 0 | 0 | Volume can not be brought online because its raw size is larger than maximum allowed size. The string sent with trap specifies na… |
1.3.6.1.4.1.789.0.324 | volumeOffline | 0 | 0 | Volume is being taken offline. The string sent with trap specifies name of affected volume and reason for being taken offline. |
1.3.6.1.4.1.789.0.344 | volumeDegradedDirty | 0 | 0 | Volume is degraded and has dirty parity. WAFL_check must be run on this volume before it can be brought online. The string sent w… |
1.3.6.1.4.1.789.0.354 | volumeError | 0 | 0 | This trap is issued when a volume can not be brought online due to an error. The string sent with trap specifies name of affecte… |
1.3.6.1.4.1.789.0.356 | volumeSelectedRootConflict | 0 | 0 | This trap is issued when multiple root volumes are detected at boot time and one is selected as the root by default. The string s… |
1.3.6.1.4.1.789.0.364 | snapmirrorSyncFailed | 0 | 0 | Synchronous SnapMirror failed and went into asynchronous mode. |
1.3.6.1.4.1.789.0.366 | snapmirrorSyncOk | 0 | 0 | Synchronous SnapMirror went into synchronous mode. |
1.3.6.1.4.1.789.0.371 | chassisTemperatureShutdown | 0 | 0 | The chassis temperature is extreme. The appliance has initiated a shutdown to protect itself. The operating environment should … |
1.3.6.1.4.1.789.0.372 | chassisTemperatureWarning | 0 | 0 | The chassis temperature is either too high or too low. The temperature should be monitored and, if possible, corrected. |
1.3.6.1.4.1.789.0.375 | chassisTemperatureUnknown | 0 | 0 | The chassis temperature is unknown, because reading can't be obtained from the chassis temperature sensor. |
1.3.6.1.4.1.789.0.376 | chassisTemperatureOk | 0 | 0 | The chassis temperature is OK. |
1.3.6.1.4.1.789.0.381 | chassisCPUFanStopped | 0 | 0 | One or more CPU fans have stopped. The appliance has initiated a shutdown to protect itself. A new motherboard may be required … |
1.3.6.1.4.1.789.0.383 | chassisCPUFanSlow | 0 | 0 | A CPU fan is spinning too slowly. A new motherboard may be required to correct the fan. Contact customer support for direction. |
... |