One or more of the storage interface modules in a
disk shelf has failed. Some shelf designs combine the
enclosure monitoring hardware function into the module
that operates the fibre channel loop or SCSI in the
shelf. This failure is of the storage interface
itself, not a failure of the enclosure monitoring,
which may be able to continue. This failure may make
one or more disks in the shelf or in the loop or bus
unavailable.
Parsed from file netapp_2_2_2.mib.txt
Company: None
Module: NETAPP-MIB
One or more of the storage interface modules in a
disk shelf has failed. Some shelf designs combine the
enclosure monitoring hardware function into the module
that operates the fibre channel loop or SCSI in the
shelf. This failure is of the storage interface
itself, not a failure of the enclosure monitoring,
which may be able to continue. This failure may make
one or more disks in the shelf or in the loop or bus
unavailable.
Parsed from file NETWORK-APPLIANCE-MIB.mib
Module: NETWORK-APPLIANCE-MIB
Vendor: Network Appliance Corporation
Module: NETWORK-APPLIANCE-MIB
[Automatically extracted from oidview.com]
shelfIFModuleFailed NOTIFICATION-TYPE OBJECTS {productTrapData, productSerialNum} STATUS current DESCRIPTION "One or more of the storage interface modules in a disk shelf has failed. Some shelf designs combine the enclosure monitoring hardware function into the module that operates the fibre channel loop or SCSI in the shelf. This failure is of the storage interface itself, not a failure of the enclosure monitoring, which may be able to continue. This failure may make one or more disks in the shelf or in the loop or bus unavailable." ::= { netapp 0 473 }
shelfIFModuleFailed NOTIFICATION-TYPE OBJECTS {productTrapData, productSerialNum} STATUS current DESCRIPTION "One or more of the storage interface modules in a disk shelf has failed. Some shelf designs combine the enclosure monitoring hardware function into the module that operates the fibre channel loop or SCSI in the shelf. This failure is of the storage interface itself, not a failure of the enclosure monitoring, which may be able to continue. This failure may make one or more disks in the shelf or in the loop or bus unavailable." ::= { netapp 0 473 }
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.789.0.424 | writeVerificationFailed | 0 | 0 | A write has failed a verification test on a SnapValidator enabled volume. |
1.3.6.1.4.1.789.0.434 | prefDCDisconnect | 0 | 0 | All connections to domain controllers in the preferred domain controllers list have been lost. |
1.3.6.1.4.1.789.0.435 | domainControllerDisconnect | 0 | 0 | A CIFS domain controller connection to the filer has failed. |
1.3.6.1.4.1.789.0.436 | dcPasswdChangeFailed | 0 | 0 | An attempt to change the filer's password with the domain controller has failed. |
1.3.6.1.4.1.789.0.437 | domainControllerConnected | 0 | 0 | A CIFS domain controller connection to the filer has been established. |
1.3.6.1.4.1.789.0.444 | plexFailed | 0 | 0 | This trap is issued when one plex of a mirrored traditional volume or aggregate is failed. The string sent with this trap specifi… |
1.3.6.1.4.1.789.0.454 | plexOffline | 0 | 0 | This trap is issued when a plex becomes offline. The string sent with this trap specifies name of affected plex or mirrored tradi… |
1.3.6.1.4.1.789.0.464 | shelfSESElectronicsFailed | 0 | 0 | One or more of the enclosure services devices in a disk shelf has failed. Some shelf designs combine the enclosure monitoring ha… |
1.3.6.1.4.1.789.0.467 | shelfSESElectronicsInfo | 0 | 0 | A previously reported failure of an enclosure services device in a disk shelf has been corrected, or the device has reported info… |
1.3.6.1.4.1.789.0.475 | shelfIFModuleWarning | 0 | 0 | One or more of the storage interface modules in a disk shelf has a warning condition. Some shelf designs combine the enclosure m… |
1.3.6.1.4.1.789.0.477 | shelfIFModuleInfo | 0 | 0 | A previously reported failure of a disk shelf interface module has been corrected, or the module has reported information that do… |
1.3.6.1.4.1.789.0.482 | maxDirSizeAlert | 0 | 0 | A directory has reached its maxdirsize limit. Either increase the maxdirsize or clean up the directory. |
1.3.6.1.4.1.789.0.485 | maxDirSizeWarning | 0 | 0 | A directory is getting close to its maxdirsize limit. Either increase the maxdirsize or clean up the directory. |
1.3.6.1.4.1.789.0.497 | cifsStatsExhaustMemCtrlBlk | 0 | 0 | A request for a CIFS control block can not be granted. All control blocks are in use. |
1.3.6.1.4.1.789.0.501 | chassisPSRemovedxMinShutdown | 0 | 0 | Power Supply Unit is removed from the system. System will be shutdown in x minutes if it is not put back. |
1.3.6.1.4.1.789.0.505 | chassisPSUsMismatch | 0 | 0 | Power Supply Units in the system are of different type. Please replace them with correct Power Supply Units. |
1.3.6.1.4.1.789.0.511 | chassisFanFailxMinShutdown | 0 | 0 | Multiple chassis fan failure. System will shut down in a few minutes if not corrected. |
1.3.6.1.4.1.789.0.515 | chassisPSUwrongInput | 0 | 0 | Power Supply Unit (PSU) in the system is connected to an incompatible external power source. Please change the power source being… |
1.3.6.1.4.1.789.0.521 | powerSupplyFanFailxMinShutdown | 0 | 0 | Multiple power supply fans failure. System will shut down in a few minutes if not corrected. |
... |