Reference record for OID 1.3.6.1.4.1.818.1.1.11.7.1



parent
1.3.6.1.4.1.818.1.1.11.7 (upsTest_first)
node code
1
node name
upsTestId_first
dot oid
1.3.6.1.4.1.818.1.1.11.7.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestId_first(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestId_first
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/11/7/1

    Description by mibdepot

    The test is named by an OBJECT IDENTIFIER which
    allows a standard mechanism for the initiation of
    tests, including the well known tests identified in
    this document as well as those introduced by a
    particular implementation, i.e., as documented in the
    private enterprise MIB definition for the device.

    Setting this variable initiates the named test. Sets
    to this variable require the presence of
    upsTestSpinLock in the same SNMP message.

    The set request will be rejected with an appropriate
    error message if the requested test cannot be
    performed, including attempts to start a test when
    another test is already in progress. The status of
    the current or last test is maintained in
    upsTestResultsSummary. Tests in progress may be
    aborted by setting the upsTestId variable to
    upsTestAbortTestInProgress.

    Read operations return the value of the name of the
    test in progress if a test is in progress or the name
    of the last test performed if no test is in progress,
    unless no test has been run, in which case the well
    known value upsTestNoTestsInitiated is returned.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsTestId_first OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*)" ::= { upsTest_first 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.7.1.0 0 0 0 upsTestId_first

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.7.2 upsTestSpinLock_first 1 1 A spin lock on the test subsystem. The spinlock is
    used as follows.

    Before starting a test, a manager-station should make
    sure th…
    1.3.6.1.4.1.818.1.1.11.7.3 upsTestResultsSummary_first 1 1 The results of the current or last UPS diagnostics
    test performed. The values for donePass(1),
    doneWarning(2), and doneError(3) …
    1.3.6.1.4.1.818.1.1.11.7.4 upsTestResultsDetail_first 1 1 Additional information about upsTestResultsSummary.
    If no additional information available, a zero length
    string is returned.(*)
    1.3.6.1.4.1.818.1.1.11.7.5 upsTestStartTime_first 1 1 The value of sysUpTime at the time the test in
    progress was initiated, or, if no test is in progress,
    the time the previous test …
    1.3.6.1.4.1.818.1.1.11.7.6 upsTestElapsedTime_first 1 1 The amount of time, in TimeTicks, since the test in
    progress was initiated, or, if no test is in progress,
    the previous test took…
    1.3.6.1.4.1.818.1.1.11.7.7 upsWellKnownTests_first 5 5 None