Reference record for OID 1.3.6.1.4.1.818.1.1.11.7.5



parent
1.3.6.1.4.1.818.1.1.11.7 (upsTest_first)
node code
5
node name
upsTestStartTime_first
dot oid
1.3.6.1.4.1.818.1.1.11.7.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsTest_first(7) upsTestStartTime_first(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsTest_first/upsTestStartTime_first
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/11/7/5

    Description by mibdepot

    The value of sysUpTime at the time the test in
    progress was initiated, or, if no test is in progress,
    the time the previous test was initiated. If the
    value of upsTestResultsSummary is noTestsInitiated(6),
    upsTestStartTime has the value 0.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsTestStartTime_first OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*)" ::= { upsTest_first 5 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.7.5.0 0 0 0 upsTestStartTime_first

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.7.1 upsTestId_first 1 1 The test is named by an OBJECT IDENTIFIER which
    allows a standard mechanism for the initiation of
    tests, including the well known…
    1.3.6.1.4.1.818.1.1.11.7.2 upsTestSpinLock_first 1 1 A spin lock on the test subsystem. The spinlock is
    used as follows.

    Before starting a test, a manager-station should make
    sure th…
    1.3.6.1.4.1.818.1.1.11.7.3 upsTestResultsSummary_first 1 1 The results of the current or last UPS diagnostics
    test performed. The values for donePass(1),
    doneWarning(2), and doneError(3) …
    1.3.6.1.4.1.818.1.1.11.7.4 upsTestResultsDetail_first 1 1 Additional information about upsTestResultsSummary.
    If no additional information available, a zero length
    string is returned.(*)
    1.3.6.1.4.1.818.1.1.11.7.6 upsTestElapsedTime_first 1 1 The amount of time, in TimeTicks, since the test in
    progress was initiated, or, if no test is in progress,
    the previous test took…
    1.3.6.1.4.1.818.1.1.11.7.7 upsWellKnownTests_first 5 5 None