The requested state of the audible alarm. When in
the disabled state, the audible alarm should never
sound. The enabled state is self-describing. Setting
this object to muted(3) when the audible alarm is
sounding shall temporarily silence the alarm. It will
remain muted until it would normally stop sounding and
the value returned for read operations during this
period shall equal muted(3). At the end of this
period, the value shall revert to enabled(2). Writes
of the value muted(3) when the audible alarm is not
sounding shall be accepted but otherwise shall have no
effect.(*)
Parsed from file GE_PARALLELUPS.mib.txt
Company: ge
Module: GE_PARALLELUPS
Vendor: IMV Victron bv
Module: GE_PARALLELUPS
[Automatically extracted from oidview.com]
upsConfigAudibleStatus_third OBJECT-TYPE SYNTAX Integer32 { disabled(1), enabled(2), muted(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*)" ::= { upsConfig_third 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.818.1.1.13.9.8.0 | 0 | 0 | 0 | upsConfigAudibleStatus_third |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.818.1.1.13.9.1 | upsConfigInputVoltage_third | 1 | 1 | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an atte… |
1.3.6.1.4.1.818.1.1.13.9.2 | upsConfigInputFreq_third | 1 | 1 | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this… |
1.3.6.1.4.1.818.1.1.13.9.3 | upsConfigOutputVoltage_third | 1 | 1 | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an att… |
1.3.6.1.4.1.818.1.1.13.9.4 | upsConfigOutputFreq_third | 1 | 1 | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set thi… |
1.3.6.1.4.1.818.1.1.13.9.5 | upsConfigOutputVA_third | 1 | 1 | The magnitude of the nominal Volt-Amp rating.(*) |
1.3.6.1.4.1.818.1.1.13.9.6 | upsConfigOutputPower_third | 1 | 1 | The magnitude of the nominal true power rating.(*) |
1.3.6.1.4.1.818.1.1.13.9.7 | upsConfigLowBattTime_third | 1 | 1 | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (d… |
1.3.6.1.4.1.818.1.1.13.9.9 | upsConfigLowVoltageTransferPoint_third | 1 | 1 | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
1.3.6.1.4.1.818.1.1.13.9.10 | upsConfigHighVoltageTransferPoint_third | 1 | 1 | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
1.3.6.1.4.1.818.1.1.13.9.11 | upsConfigBatteryCapacity_third | 1 | 1 | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
1.3.6.1.4.1.818.1.1.13.9.12 | upsConfigBatteryChargeCurrent_third | 1 | 1 | The maximum battery charge current, including external chargers. |
1.3.6.1.4.1.818.1.1.13.9.13 | upsConfigNoLoadShutdown_third | 1 | 1 | Dis- or enable 'no load' shutdown from the contact interface. |
1.3.6.1.4.1.818.1.1.13.9.14 | upsConfigStartDelay_third | 1 | 1 | Minimum required autonomy time before the UPS may perform an autorestart. |