upsConfig_third OBJECT IDENTIFIER ::= { geThirdUPS 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.818.1.1.13.9.1 | upsConfigInputVoltage_third | 1 | 1 | The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an atte… |
1.3.6.1.4.1.818.1.1.13.9.2 | upsConfigInputFreq_third | 1 | 1 | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this… |
1.3.6.1.4.1.818.1.1.13.9.3 | upsConfigOutputVoltage_third | 1 | 1 | The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an att… |
1.3.6.1.4.1.818.1.1.13.9.4 | upsConfigOutputFreq_third | 1 | 1 | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set thi… |
1.3.6.1.4.1.818.1.1.13.9.5 | upsConfigOutputVA_third | 1 | 1 | The magnitude of the nominal Volt-Amp rating.(*) |
1.3.6.1.4.1.818.1.1.13.9.6 | upsConfigOutputPower_third | 1 | 1 | The magnitude of the nominal true power rating.(*) |
1.3.6.1.4.1.818.1.1.13.9.7 | upsConfigLowBattTime_third | 1 | 1 | The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (d… |
1.3.6.1.4.1.818.1.1.13.9.8 | upsConfigAudibleStatus_third | 1 | 1 | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state i… |
1.3.6.1.4.1.818.1.1.13.9.9 | upsConfigLowVoltageTransferPoint_third | 1 | 1 | The minimum input line voltage allowed before the UPS system transfers to battery backup.(*) |
1.3.6.1.4.1.818.1.1.13.9.10 | upsConfigHighVoltageTransferPoint_third | 1 | 1 | The maximum line voltage allowed before the UPS system transfers to battery backup.(*) |
1.3.6.1.4.1.818.1.1.13.9.11 | upsConfigBatteryCapacity_third | 1 | 1 | The installed battery capacity. This value is the 'factory'-value, not the value after calibration. |
1.3.6.1.4.1.818.1.1.13.9.12 | upsConfigBatteryChargeCurrent_third | 1 | 1 | The maximum battery charge current, including external chargers. |
1.3.6.1.4.1.818.1.1.13.9.13 | upsConfigNoLoadShutdown_third | 1 | 1 | Dis- or enable 'no load' shutdown from the contact interface. |
1.3.6.1.4.1.818.1.1.13.9.14 | upsConfigStartDelay_third | 1 | 1 | Minimum required autonomy time before the UPS may perform an autorestart. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.818.1.1.13.1 | upsIdent_third | 9 | 18 | None |
1.3.6.1.4.1.818.1.1.13.2 | upsBattery_third | 7 | 14 | None |
1.3.6.1.4.1.818.1.1.13.3 | upsInput_third | 3 | 13 | None |
1.3.6.1.4.1.818.1.1.13.4 | upsOutput_third | 4 | 13 | None |
1.3.6.1.4.1.818.1.1.13.5 | upsBypass_third | 3 | 10 | None |
1.3.6.1.4.1.818.1.1.13.6 | upsAlarm_third | 4 | 35 | None |
1.3.6.1.4.1.818.1.1.13.7 | upsTest_third | 7 | 18 | None |
1.3.6.1.4.1.818.1.1.13.8 | upsControl_third | 13 | 28 | None |
1.3.6.1.4.1.818.1.1.13.10 | upsGetSet_third | 24 | 54 | None |
1.3.6.1.4.1.818.1.1.13.11 | geUPSTraps_third | 51 | 51 | None |