Reference record for OID 1.3.6.1.4.1.818.1.1.14.8


parent
1.3.6.1.4.1.818.1.1.14 (geFourthUPS)
node code
8
node name
upsControl_fourth
dot oid
1.3.6.1.4.1.818.1.1.14.8
type
OBJECT IDENTIFIER
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsControl_fourth(8)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsControl_fourth
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/14/8

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsControl_fourth OBJECT IDENTIFIER ::= { geFourthUPS 8 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.8.1 upsShutdownType_fourth 1 1 This object determines the nature of the action to be
    taken at the time when the countdown of the
    upsShutdownAfterDelay and upsRe…
    1.3.6.1.4.1.818.1.1.14.8.2 upsShutdownAfterDelay_fourth 1 1 Setting this object will shutdown (i.e., turn off)
    either the UPS output or the UPS system (as determined
    by the value of upsShut…
    1.3.6.1.4.1.818.1.1.14.8.3 upsStartupAfterDelay_fourth 1 1 Setting this object will start the output after the
    indicated number of seconds, including starting the
    UPS, if necessary. Setti…
    1.3.6.1.4.1.818.1.1.14.8.4 upsRebootWithDuration_fourth 1 1 Setting this object will immediately shutdown (i.e.,
    turn off) either the UPS output or the UPS system (as
    determined by the valu…
    1.3.6.1.4.1.818.1.1.14.8.5 upsAutoRestart_fourth 1 1 Setting this object to 'on' will cause the UPS system
    to restart after a shutdown if the shutdown occurred
    during a power loss as…
    1.3.6.1.4.1.818.1.1.14.8.6 upsReceptaclesNum_fourth 1 1 The number of receptacles utilized in this device.
    This entry indicates the number of rows in the receptacle
    table.
    1.3.6.1.4.1.818.1.1.14.8.7 upsReceptacleTable_fourth 1 3 A list of receptacle table entries. The number of
    entries is given by the value of upsReceptacleNum.
    1.3.6.1.4.1.818.1.1.14.8.8 upsUPSMode_fourth 1 1 The operation mode off the UPS. Off-line indicates a
    mode in which the input power is transferred to the
    output directly or via a…
    1.3.6.1.4.1.818.1.1.14.8.9 upsRectifierOnOff_fourth 1 1 The present state of the rectifier. Setting this
    object to 'on' will cause the rectifier to be turned
    on. Setting this object to …
    1.3.6.1.4.1.818.1.1.14.8.10 upsBatteryChargeMethod_fourth 1 1 The present state of the charge method. Setting this
    object to 'Normal charge' will cause the battery to be
    charged using the nor…
    1.3.6.1.4.1.818.1.1.14.8.11 upsInverterOnOff_fourth 1 1 The present state of the inverter. Setting this
    object to 'on' will cause the inverter to be turned
    on. Setting this object to 'o…
    1.3.6.1.4.1.818.1.1.14.8.12 upsBypassOnOff_fourth 1 1 The present state of the bypass. Setting this
    object to 'on' will cause the bypass to be activated.
    Setting this object to 'off' …
    1.3.6.1.4.1.818.1.1.14.8.13 upsLoadSource_fourth 1 1 The present source of the load. Setting this
    object to 'On bypass' will cause the load to be
    supplied by the bypass.
    Setting this …

    Brothers (10)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.1 upsIdent_fourth 9 18 None
    1.3.6.1.4.1.818.1.1.14.2 upsBattery_fourth 7 14 None
    1.3.6.1.4.1.818.1.1.14.3 upsInput_fourth 3 13 None
    1.3.6.1.4.1.818.1.1.14.4 upsOutput_fourth 4 13 None
    1.3.6.1.4.1.818.1.1.14.5 upsBypass_fourth 3 10 None
    1.3.6.1.4.1.818.1.1.14.6 upsAlarm_fourth 4 35 None
    1.3.6.1.4.1.818.1.1.14.7 upsTest_fourth 7 18 None
    1.3.6.1.4.1.818.1.1.14.9 upsConfig_fourth 14 28 None
    1.3.6.1.4.1.818.1.1.14.10 upsGetSet_fourth 24 54 None
    1.3.6.1.4.1.818.1.1.14.11 geUPSTraps_fourth 51 51 None