Reference record for OID 1.3.6.1.4.1.818.1.1.14.9.1



parent
1.3.6.1.4.1.818.1.1.14.9 (upsConfig_fourth)
node code
1
node name
upsConfigInputVoltage_fourth
dot oid
1.3.6.1.4.1.818.1.1.14.9.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsConfig_fourth(9) upsConfigInputVoltage_fourth(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsConfig_fourth/upsConfigInputVoltage_fourth
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/14/9/1

    Description by mibdepot

    The magnitude of the nominal input voltage. On those
    systems which support read-write access to this
    object, if there is an attempt to set this variable to
    a value that is not supported, the request must be
    rejected and the agent shall respond with an
    appropriate error message, i.e., badValue for SNMPv1,
    or inconsistentValue for SNMPv2.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsConfigInputVoltage_fourth OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-write STATUS current DESCRIPTION "The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*)" ::= { upsConfig_fourth 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.9.1.0 0 0 0 upsConfigInputVoltage_fourth

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.9.2 upsConfigInputFreq_fourth 1 1 The nominal input frequency. On those systems which
    support read-write access to this object, if there is
    an attempt to set this…
    1.3.6.1.4.1.818.1.1.14.9.3 upsConfigOutputVoltage_fourth 1 1 The magnitude of the nominal output voltage. On
    those systems which support read-write access to this
    object, if there is an att…
    1.3.6.1.4.1.818.1.1.14.9.4 upsConfigOutputFreq_fourth 1 1 The nominal output frequency. On those systems which
    support read-write access to this object, if there is
    an attempt to set thi…
    1.3.6.1.4.1.818.1.1.14.9.5 upsConfigOutputVA_fourth 1 1 The magnitude of the nominal Volt-Amp rating.(*)
    1.3.6.1.4.1.818.1.1.14.9.6 upsConfigOutputPower_fourth 1 1 The magnitude of the nominal true power rating.(*)
    1.3.6.1.4.1.818.1.1.14.9.7 upsConfigLowBattTime_fourth 1 1 The value of upsEstimatedMinutesRemaining at which a
    lowBattery condition is declared. For agents which
    support only discrete (d…
    1.3.6.1.4.1.818.1.1.14.9.8 upsConfigAudibleStatus_fourth 1 1 The requested state of the audible alarm. When in
    the disabled state, the audible alarm should never
    sound. The enabled state i…
    1.3.6.1.4.1.818.1.1.14.9.9 upsConfigLowVoltageTransferPoint_fourth 1 1 The minimum input line voltage allowed before the UPS
    system transfers to battery backup.(*)
    1.3.6.1.4.1.818.1.1.14.9.10 upsConfigHighVoltageTransferPoint_fourth 1 1 The maximum line voltage allowed before the UPS
    system transfers to battery backup.(*)
    1.3.6.1.4.1.818.1.1.14.9.11 upsConfigBatteryCapacity_fourth 1 1 The installed battery capacity. This value is the 'factory'-value,
    not the value after calibration.
    1.3.6.1.4.1.818.1.1.14.9.12 upsConfigBatteryChargeCurrent_fourth 1 1 The maximum battery charge current, including external chargers.
    1.3.6.1.4.1.818.1.1.14.9.13 upsConfigNoLoadShutdown_fourth 1 1 Dis- or enable 'no load' shutdown from the contact interface.
    1.3.6.1.4.1.818.1.1.14.9.14 upsConfigStartDelay_fourth 1 1 Minimum required autonomy time before the UPS may perform an
    autorestart.