The value of this object indicates the behaviour
of the equipment when a requested address
conversion can not be made because the address is
not found in the address conversion tables
(fcwAddrConvIncomingCallTable or
fcwAddrConvOutgoingCallTable). In this case the
call will be cleared when 'checking' is enabled.
The authorized values are :
off : no checking,
onIncomingCall : checking on incoming calls,
onOutgoingCall : checking on outgoing calls,
onIcomingCallAndOutgoingCall : checking on
incoming and outgoing calls.
The default value is 'off'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object indicates the behaviour
of the equipment when a requested address
conversion can not be made because the address is
not found in the address conversion tables
(fcwAddrConvIncomingCallTable or
fcwAddrConvOutgoingCallTable). In this case the
call will be cleared when 'checking' is enabled.
The authorized values are :
off : no checking,
onIncomingCall : checking on incoming calls,
onOutgoingCall : checking on outgoing calls,
onIcomingCallAndOutgoingCall : checking on
incoming and outgoing calls.
The default value is 'off'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfnSigConversionAddressCheck OBJECT-TYPE SYNTAX INTEGER { off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'." ::= { fclX25CfnSignallingEntry 13 }
fclX25CfnSigConversionAddressCheck OBJECT-TYPE SYNTAX INTEGER { off(1), onIncomingCall(2), onOutgoingCall(3), onIncomingCallAndOutgoingCall(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the address is not found in the address conversion tables (fcwAddrConvIncomingCallTable or fcwAddrConvOutgoingCallTable). In this case the call will be cleared when 'checking' is enabled. The authorized values are : off : no checking, onIncomingCall : checking on incoming calls, onOutgoingCall : checking on outgoing calls, onIcomingCallAndOutgoingCall : checking on incoming and outgoing calls. The default value is 'off'." ::= { fclX25CfnSignallingEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.10.30.1.1 | fclX25CfnSigConfigId | 0 | 0 | The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is un… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.4 | fclX25CfnSigSubAddressTransmission | 0 | 0 | The value of this object indicates whether the sub-address of the called address field of the call request packet received on a P… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.10 | fclX25CfnSigConversionAimedPoint | 0 | 0 | The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in ma… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.11 | fclX25CfnSigConversionIncomingCall | 0 | 0 | The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.12 | fclX25CfnSigConversionOutgoingCall | 0 | 0 | The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.14 | fclX25CfnSigConvMultiCalledAddrInCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.15 | fclX25CfnSigConvMultiCallingAddrInCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.16 | fclX25CfnSigConvMultiCalledAddrOutCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.17 | fclX25CfnSigConvMultiCallingAddrOutCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.22 | fclX25CfnSigT11CallResponseTimer | 0 | 0 | The value of this object is the maximum time (in seconds) the equipment will wait for a response to a call request packet sent on… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.25 | fclX25CfnSigCallAcceptedFormat | 0 | 0 | The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddres… |