The value of this object defines the format of an
outgoing call connected packet. The authorized
values are :
noFacilitiesNoAddresses : no facility length
and facility fields, calling and called
DTE address lengths set to 0,
facilitiesNoAddresses : facility length and
facility fields, calling and called DTE
address lengths set to 0,
facilitiesNoCheckedAdresses : facility length
and facility fields, calling and called
DTE address lengths different from 0,
addresses are not checked (???),
facilitiesCheckedAddresses : facility length
and facility fields, calling and called
DTE address lengths different from 0,
addresses are checked (???),
The default value is 'noFacilitiesNoAddresses'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object defines the format of an
outgoing call connected packet. The authorized
values are :
noFacilitiesNoAddresses : no facility length
and facility fields, calling and called
DTE address lengths set to 0,
facilitiesNoAddresses : facility length and
facility fields, calling and called DTE
address lengths set to 0,
facilitiesNoCheckedAdresses : facility length
and facility fields, calling and called
DTE address lengths different from 0,
addresses are not checked (???),
facilitiesCheckedAddresses : facility length
and facility fields, calling and called
DTE address lengths different from 0,
addresses are checked (???),
The default value is 'noFacilitiesNoAddresses'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfnSigCallAcceptedFormat OBJECT-TYPE SYNTAX INTEGER { noFacilitiesNoAddresses(3), facilitiesNoAddresses(2), facilitiesNotCheckedAddresses(4), facilitiesCheckedAddresses(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddresses : no facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoAddresses : facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoCheckedAdresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are not checked (???), facilitiesCheckedAddresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are checked (???), The default value is 'noFacilitiesNoAddresses'." ::= { fclX25CfnSignallingEntry 25 }
fclX25CfnSigCallAcceptedFormat OBJECT-TYPE SYNTAX INTEGER { noFacilitiesNoAddresses(3), facilitiesNoAddresses(2), facilitiesNotCheckedAddresses(4), facilitiesCheckedAddresses(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines the format of an outgoing call connected packet. The authorized values are : noFacilitiesNoAddresses : no facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoAddresses : facility length and facility fields, calling and called DTE address lengths set to 0, facilitiesNoCheckedAdresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are not checked (???), facilitiesCheckedAddresses : facility length and facility fields, calling and called DTE address lengths different from 0, addresses are checked (???), The default value is 'noFacilitiesNoAddresses'." ::= { fclX25CfnSignallingEntry 25 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.10.30.1.1 | fclX25CfnSigConfigId | 0 | 0 | The value of this object identifies one and only one X25 inter-node configuration. The possible values are : '0..199. If it is un… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.4 | fclX25CfnSigSubAddressTransmission | 0 | 0 | The value of this object indicates whether the sub-address of the called address field of the call request packet received on a P… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.10 | fclX25CfnSigConversionAimedPoint | 0 | 0 | The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in ma… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.11 | fclX25CfnSigConversionIncomingCall | 0 | 0 | The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.12 | fclX25CfnSigConversionOutgoingCall | 0 | 0 | The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.13 | fclX25CfnSigConversionAddressCheck | 0 | 0 | The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the… |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.14 | fclX25CfnSigConvMultiCalledAddrInCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appele multi-criteres en entree |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.15 | fclX25CfnSigConvMultiCallingAddrInCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appelant multi-criteres en entree |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.16 | fclX25CfnSigConvMultiCalledAddrOutCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appele multi-criteres en sortie |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.17 | fclX25CfnSigConvMultiCallingAddrOutCall | 0 | 0 | Numero d'identification pour conversion d'adresse d'appelant multi-criteres en sortie |
1.3.6.1.4.1.866.20.1.20.50.10.30.1.22 | fclX25CfnSigT11CallResponseTimer | 0 | 0 | The value of this object is the maximum time (in seconds) the equipment will wait for a response to a call request packet sent on… |