yes(1) indicates that the conditions specified in
cpsGroupCtrl.0 match the Groups value for this
device. no(2) means that there is no match.
notApplicable(3) indicates that cpsGroupCtrl.0 is null
and therefore no comparison was performed.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cetct100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cetct100Entry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.12.1.1 | cetct100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.2 | cetct100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.3 | cetct100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.4 | cetct100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.6 | cetct100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.7 | cetct100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.8 | cetct100FirmwareRevision | 0 | 0 | The firmware revision level for this device. |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.9 | cetct100TPLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.10 | cetct100Collision | 0 | 0 | This status variable indicates whether or not an Ethernet collision occurred during the most recent polling cycle. |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.11 | cetct100CoaxActivity | 0 | 0 | This status variable indicates whether or not Ethernet traffic was detected on the Coax interface during the most recent polling … |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.12 | cetct100TPActivity | 0 | 0 | This status variable indicates whether or not Ethernet traffic was detected on the Twisted Pair interface during the most recent … |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.13 | cetct100CollisionsPerMinute | 0 | 0 | The number of Ethernet collisions that occurred during the most recently completed measured minute. Every 60 seconds, the device … |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.14 | cetct100CollisionsPerHour | 0 | 0 | The number of Ethernet collisions that occurred during the most recently completed measured hour. Every 60 minutes, the device mo… |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.15 | cetct100ConnA | 0 | 0 | The style of media connector built into this device. |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.16 | cetct100ConnB | 0 | 0 | The style of media connector built into this device. |
1.3.6.1.4.1.868.2.4.1.2.2.12.1.17 | cetct100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |