Local receive clock usage. Some types of high-speed
serial equipment read the data signal on the rising edge
of the clock, and others on the falling edge of the clock.
The CPSVT100-xxx High Speed Serial converter is compatible
with both types of equipment. The expectations of the
equipment attached to the copper interface can be matched
via jumper settings on the converter.
The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status
variables indicate the status of these jumpers. Most
high-speed serial equipment uses the rising edge of
the clock.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cpsvt100InvertRX OBJECT-TYPE SYNTAX INTEGER { rising(1), falling(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of the clock. The CPSVT100-xxx High Speed Serial converter is compatible with both types of equipment. The expectations of the equipment attached to the copper interface can be matched via jumper settings on the converter. The cpsvt100InvertTX(16) and cpsvt100InvertRX(17) status variables indicate the status of these jumpers. Most high-speed serial equipment uses the rising edge of the clock." ::= { cpsvt100Entry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.18.1.1 | cpsvt100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.2 | cpsvt100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.3 | cpsvt100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.4 | cpsvt100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.5 | cpsvt100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.6 | cpsvt100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.7 | cpsvt100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.8 | cpsvt100CopperLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.9 | cpsvt100Fault | 0 | 0 | Value is yes(1) when either CopperLink or FiberLink has value linkDown(2) |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.10 | cpsvt100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.11 | cpsvt100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.12 | cpsvt100TermTiming | 0 | 0 | Local Terminal Timing setting. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends to… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.13 | cpsvt100LoopBack | 0 | 0 | Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is en… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.14 | cpsvt100CableMode | 0 | 0 | A description of the type of cable that is attached to the Copper interface of the local device. |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.15 | cpsvt100DCE | 0 | 0 | An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this st… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.16 | cpsvt100InvertTX | 0 | 0 | Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and … |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.18 | cpsvt100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.19 | cpsvt100FirmwareRev | 0 | 0 | Local firmware revision. |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.20 | cpsvt100RmtDetected | 0 | 0 | Has the value yes(1) if management communcations have been established with a remote media converter. |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.21 | cpsvt100RmtTermTiming | 0 | 0 | Local Terminal Timing setting of the remotely managed CPSVTxxx. Terminal timing is a signal sent from a DCE to a DTE to control … |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.22 | cpsvt100RmtLoopBack | 0 | 0 | Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is en… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.23 | cpsvt100RmtCableMode | 0 | 0 | A description of the type of cable that is attached to the Copper interface of the local device. |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.24 | cpsvt100RmtDCE | 0 | 0 | An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this st… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.25 | cpsvt100RmtInvertTX | 0 | 0 | Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and … |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.26 | cpsvt100RmtInvertRX | 0 | 0 | Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and o… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.27 | cpsvt100RmtConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.28 | cpsvt100RmtFirmwareRev | 0 | 0 | Local firmware revision. |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.29 | cpsvt100RmtCopperLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.30 | cpsvt100RmtFiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.18.1.31 | cpsvt100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |