Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.24.1



parent
1.3.6.1.4.1.868.2.4.1.2.2.24 (crmfe100Table)
node code
1
node name
crmfe100Entry
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.24.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) crmfe100Table(24) crmfe100Entry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/crmfe100Table/crmfe100Entry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/24/1

    Description by circitor

    Status and configuration entries for a single CRMFE100

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    crmfe100Entry OBJECT-TYPE SYNTAX Crmfe100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CRMFE100" INDEX { crmfe100BiaIndex, crmfe100SlotIndex } ::= { crmfe100Table 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Children (49)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.1 crmfe100BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.2 crmfe100SlotIndex 0 0 The slot in which the device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.3 crmfe100Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.4 crmfe100MRevision 0 0 The marketing revision of this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.5 crmfe100CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.6 crmfe100SerialNumber 0 0 The serial number of this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.7 crmfe100ConnA 0 0 The style of Fiber connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.8 crmfe100ConnB 0 0 The style of Copper connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.9 crmfe100TPLink 0 0 Status of Copper Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.10 crmfe100FiberLink 0 0 Status of Fiber Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.11 crmfe100Fault 0 0 Value is yes(1) when either CopperLink or FiberLink
    has value linkDown(2)
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.12 crmfe100Autonegot 0 0 Autonegotiation configuration for this device.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.13 crmfe100Enabled 0 0 When the Enabled configuration item is set to no(2),
    the converter passes no network traffic in either
    direction.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.14 crmfe100Pause 0 0 The Pause feature allows Ethernet MACs that support it to
    send data pacing 'Pause' messages to each other.
    Support for Pause is n…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.15 crmfe100LinkPassThrough 0 0 This configuration item allows Link Pass Through to
    be enabled(1) or disabled(2). Link Passthrough causes
    loss of link on one sid…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.16 crmfe100AutoCross 0 0 On certain devices, it is possible for hardware to
    automatically correct errors in cable selection, making
    the distinction betwee…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.17 crmfe100TPActivity 0 0 Twisted Pair Activity. Some versions of the CRMFE100 do
    not support the reporting of interface activity. The value
    of this variab…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.18 crmfe100FiberActivity 0 0 Fiber Activity. Some versions of the CRMFE100 do not support
    the reporting of interface activity. The value of this
    variable for …
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.19 crmfe100ConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.20 crmfe100FarEndFault 0 0 Far End Fault configuration of this device. Far End Fault
    causes the fiber transmitter to generate a Far End Fault
    pattern upon …
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.21 crmfe100NetworkMode 0 0 Read-only indicator for High Speed Token Ring jumper
    configuration. If the variable reads tokenRing(1), then the
    converter is jum…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.22 crmfe100UpTime 0 0 Time since the last reboot in Time Ticks (hundredths of
    seconds). If the value 0 is written to this variable, the
    timer is reset.…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.23 crmfe100FirmwareRevision 0 0 Firmware revision level of this CRMFE100.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.24 crmfe100RmtDetected 0 0 Has the value yes(1) if management communcations
    have been established with a remote media converter.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.25 crmfe100RmtTPLink 0 0 Status of Copper Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.26 crmfe100RmtFiberLink 0 0 Status of Fiber Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.27 crmfe100RmtFault 0 0 Value is yes(1) when either TPLink or FiberLink
    has value linkDown(2)
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.28 crmfe100RmtAutonegot 0 0 Autonegotiation configuration for this device.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.29 crmfe100RmtPause 0 0 The Pause feature allows Ethernet MACs that support it to
    send data pacing 'Pause' messages to each other.
    Support for Pause is n…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.30 crmfe100RmtLinkPassThrough 0 0 This configuration item allows Link Pass Through to
    be enabled(1) or disabled(2). Link Passthrough causes
    loss of link on one sid…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.31 crmfe100RmtAutoCross 0 0 On certain devices, it is possible for hardware to
    automatically correct errors in cable selection, making
    the distinction betwee…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.32 crmfe100RmtTPActivity 0 0 Twisted Pair Activity. Some versions of the CRMFE100 do
    not support the reporting of interface activity. The value
    of this variab…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.33 crmfe100RmtFiberActivity 0 0 Fiber Activity. Some versions of the CRMFE100 do not support
    the reporting of interface activity. The value of this
    variable for …
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.34 crmfe100RmtConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.35 crmfe100RmtFarEndFault 0 0 Far End Fault configuration of this device. Far End Fault
    causes the fiber transmitter to generate a Far End Fault
    pattern upon …
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.36 crmfe100RmtLoopback 0 0 When Remote Loopback is enabled, all packets sent out from
    the local fiber interface are reflected back by the remote
    converter r…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.37 crmfe100RmtNetworkMode 0 0 Read-only indicator for High Speed Token Ring jumper
    configuration. If the variable reads tokenRing(1), then the
    converter is jum…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.38 crmfe100RmtUpTime 0 0 Time since the last reboot in Time Ticks (hundredths of
    seconds). If the value 0 is written to this variable, the
    timer is reset.…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.39 crmfe100TxFxBwa 0 0 This variable allows the control of bandwidth allocation.
    The value of this variable is entered in Kilobytes per Second,
    and is a…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.40 crmfe100FxTxBwa 0 0 This variable allows the control of bandwidth allocation.
    The value of this variable is entered in Kilobytes per Second,
    and is a…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.41 crmfe100TxBytesH 0 0 These variables measure the traffic (in Bytes) received by the
    two interfaces of the converter (and therefore transmitted by
    the …
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.42 crmfe100TxBytesL 0 0 See the DESCRIPTION for cfmfe100TxBytesH(42) above.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.43 crmfe100FxBytesH 0 0 See the DESCRIPTION for cfmfe100TxBytesH(42) above.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.44 crmfe100FxBytesL 0 0 See the DESCRIPTION for cfmfe100TxBytesH(42) above.
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.45 crmfe100MscRxBytes 0 0 This variable measures the traffic (in Bytes) received and
    transmitted by the Management Subchannel within the Fiber
    interface. '…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.46 crmfe100MscTxBytes 0 0 This variable measures the traffic (in Bytes) received and
    transmitted by the Management Subchannel within the Fiber
    interface. '…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.47 crmfe100CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.48 crmfe100MbTxFxBwa 0 0 This variable allows the control of bandwidth allocation.
    The value of this variable is entered in Megabits per Second,
    and is au…
    1.3.6.1.4.1.868.2.4.1.2.2.24.1.49 crmfe100MbFxTxBwa 0 0 This variable allows the control of bandwidth allocation.
    The value of this variable is entered in Megabits per Second,
    and is au…