This device has a jumper or switch that disables
software management of the device. When ConfigMode is
hardware(2), SNMP management is disabled, and all
configuration control comes from physical switches or
jumpers on the device.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
crs2f100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { crs2f100Entry 15 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.25.1.1 | crs2f100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.2 | crs2f100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.3 | crs2f100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.4 | crs2f100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.5 | crs2f100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.6 | crs2f100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.7 | crs2f100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.8 | crs2f100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.9 | crs2f100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.10 | crs2f100Fault | 0 | 0 | Value is yes(1) when FiberLink has value linkDown(2) |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.11 | crs2f100FirmwareRevision | 0 | 0 | The Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can … |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.12 | crs2f100Loopback | 0 | 0 | Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sen… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.13 | crs2f100DCE | 0 | 0 | An indication of whether this device is attached to a DCE (a modem) or a DTE (a terminal or computer). |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.14 | crs2f100CopperActivity | 0 | 0 | The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network por… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.16 | crs2f100RmtDetected | 0 | 0 | Has the value yes(1) if management communcations have been established with a remote media device. |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.17 | crs2f100RmtLoopback | 0 | 0 | Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sen… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.18 | crs2f100RmtDCE | 0 | 0 | This variable describes the status of a remotely managed device. This is an indicator of whether this device is attached to a DC… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.19 | crs2f100RmtCopperActivity | 0 | 0 | The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network por… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.20 | crs2f100RmtConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.25.1.21 | crs2f100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |