An arbitrary integer for identifying individual events
within the event log.
Parsed from file CISCO-DOT3-OAM-MIB.mib
Module: CISCO-DOT3-OAM-MIB
An arbitrary integer for identifying individual events
within the event log.
An arbitrary integer for identifying individual events
within the event log.
Parsed from file CISCO-DOT3-OAM-MIB.my.txt
Company: None
Module: CISCO-DOT3-OAM-MIB
An arbitrary integer for identifying individual events
within the event log.
cdot3OamEventLogIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer for identifying individual events within the event log. " ::= { cdot3OamEventLogEntry 1 }
cdot3OamEventLogIndex OBJECT-TYPE SYNTAX Gauge ACCESS not-accessible STATUS mandatory DESCRIPTION "An arbitrary integer for identifying individual events within the event log. " ::= { cdot3OamEventLogEntry 1 }
Vendor: Cisco
Module: CISCO-DOT3-OAM-MIB
[Automatically extracted from oidview.com]
cdot3OamEventLogIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer for identifying individual events within the event log. " ::= { cdot3OamEventLogEntry 1 }
cdot3OamEventLogIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An arbitrary integer for identifying individual events within the event log. " ::= { cdot3OamEventLogEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.10.136.1.6.1.2 | cdot3OamEventLogTimestamp | 0 | 0 | The value of sysUpTime at the time of the logged event. For locally generated events, the time of the event can be accurately re… |
1.3.6.1.4.1.9.10.136.1.6.1.3 | cdot3OamEventLogOui | 0 | 0 | The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organiza… |
1.3.6.1.4.1.9.10.136.1.6.1.4 | cdot3OamEventLogType | 0 | 0 | The type of event that generated this entry in the event log. When the OUI is the IEEE 802.3 OUI of 0x0180C2, the following event… |
1.3.6.1.4.1.9.10.136.1.6.1.5 | cdot3OamEventLogLocation | 0 | 0 | Whether this event occurred locally (local(1)), or was received from the OAM peer via Ethernet OAM (remote(2)). |
1.3.6.1.4.1.9.10.136.1.6.1.6 | cdot3OamEventLogWindowHi | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventWindowHi and cdot3OamEventWindowLo form an unsig… |
1.3.6.1.4.1.9.10.136.1.6.1.7 | cdot3OamEventLogWindowLo | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventWindowHi and cdot3OamEventWindowLo form an unsig… |
1.3.6.1.4.1.9.10.136.1.6.1.8 | cdot3OamEventLogThresholdHi | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventThresholdHi and cdot3OamEventThresholdLo form an… |
1.3.6.1.4.1.9.10.136.1.6.1.9 | cdot3OamEventLogThresholdLo | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventThresholdHi and cdot3OamEventThresholdLo form an… |
1.3.6.1.4.1.9.10.136.1.6.1.10 | cdot3OamEventLogValue | 0 | 0 | If the event represents a threshold crossing event, this value indicates the value of the parameter within the given window that … |
1.3.6.1.4.1.9.10.136.1.6.1.11 | cdot3OamEventLogRunningTotal | 0 | 0 | Each Event Notification TLV contains a running total of the number of times an event has occurred, as well as the number of times… |
1.3.6.1.4.1.9.10.136.1.6.1.12 | cdot3OamEventLogEventTotal | 0 | 0 | Each Event Notification TLV contains a running total of the number of times an event has occurred, as well as the number of times… |