The OUI of the entity defining the object type. All IEEE
802.3 defined events (as appearing in [802.3ah] except for the
Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification
TLVs include their OUI in the Event Notification TLV which
gets reflected here.
Parsed from file CISCO-DOT3-OAM-MIB.mib
Module: CISCO-DOT3-OAM-MIB
The OUI of the entity defining the object type. All IEEE
802.3 defined events (as appearing in [802.3ah] except for the
Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification
TLVs include their OUI in the Event Notification TLV which
gets reflected here.
The OUI of the entity defining the object type. All IEEE
802.3 defined events (as appearing in [802.3ah] except for the
Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification
TLVs include their OUI in the Event Notification TLV which
gets reflected here.
Parsed from file CISCO-DOT3-OAM-MIB.my.txt
Company: None
Module: CISCO-DOT3-OAM-MIB
The OUI of the entity defining the object type. All IEEE
802.3 defined events (as appearing in [802.3ah] except for the
Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification
TLVs include their OUI in the Event Notification TLV which
gets reflected here.
cdot3OamEventLogOui OBJECT-TYPE SYNTAX Cdot3Oui MAX-ACCESS read-only STATUS current DESCRIPTION "The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notification TLV which gets reflected here. " ::= { cdot3OamEventLogEntry 3 }
cdot3OamEventLogOui OBJECT-TYPE SYNTAX Cdot3Oui ACCESS read-only STATUS mandatory DESCRIPTION "The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notification TLV which gets reflected here. " ::= { cdot3OamEventLogEntry 3 }
Vendor: Cisco
Module: CISCO-DOT3-OAM-MIB
[Automatically extracted from oidview.com]
cdot3OamEventLogOui OBJECT-TYPE SYNTAX Cdot3Oui MAX-ACCESS read-only STATUS current DESCRIPTION "The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notification TLV which gets reflected here. " ::= { cdot3OamEventLogEntry 3 }
cdot3OamEventLogOui OBJECT-TYPE SYNTAX Cdot3Oui MAX-ACCESS read-only STATUS current DESCRIPTION "The OUI of the entity defining the object type. All IEEE 802.3 defined events (as appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notification TLV which gets reflected here. " ::= { cdot3OamEventLogEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.10.136.1.6.1.1 | cdot3OamEventLogIndex | 0 | 0 | An arbitrary integer for identifying individual events within the event log. |
1.3.6.1.4.1.9.10.136.1.6.1.2 | cdot3OamEventLogTimestamp | 0 | 0 | The value of sysUpTime at the time of the logged event. For locally generated events, the time of the event can be accurately re… |
1.3.6.1.4.1.9.10.136.1.6.1.4 | cdot3OamEventLogType | 0 | 0 | The type of event that generated this entry in the event log. When the OUI is the IEEE 802.3 OUI of 0x0180C2, the following event… |
1.3.6.1.4.1.9.10.136.1.6.1.5 | cdot3OamEventLogLocation | 0 | 0 | Whether this event occurred locally (local(1)), or was received from the OAM peer via Ethernet OAM (remote(2)). |
1.3.6.1.4.1.9.10.136.1.6.1.6 | cdot3OamEventLogWindowHi | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventWindowHi and cdot3OamEventWindowLo form an unsig… |
1.3.6.1.4.1.9.10.136.1.6.1.7 | cdot3OamEventLogWindowLo | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventWindowHi and cdot3OamEventWindowLo form an unsig… |
1.3.6.1.4.1.9.10.136.1.6.1.8 | cdot3OamEventLogThresholdHi | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventThresholdHi and cdot3OamEventThresholdLo form an… |
1.3.6.1.4.1.9.10.136.1.6.1.9 | cdot3OamEventLogThresholdLo | 0 | 0 | If the event represents a threshold crossing event, the two objects cdot3OamEventThresholdHi and cdot3OamEventThresholdLo form an… |
1.3.6.1.4.1.9.10.136.1.6.1.10 | cdot3OamEventLogValue | 0 | 0 | If the event represents a threshold crossing event, this value indicates the value of the parameter within the given window that … |
1.3.6.1.4.1.9.10.136.1.6.1.11 | cdot3OamEventLogRunningTotal | 0 | 0 | Each Event Notification TLV contains a running total of the number of times an event has occurred, as well as the number of times… |
1.3.6.1.4.1.9.10.136.1.6.1.12 | cdot3OamEventLogEventTotal | 0 | 0 | Each Event Notification TLV contains a running total of the number of times an event has occurred, as well as the number of times… |