This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
Parsed from file CISCO-OPTICAL-MONITOR-MIB.mib
Module: CISCO-OPTICAL-MONITOR-MIB
This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
Parsed from file CISCO-OPTICAL-MONITOR-MIB.my.txt
Company: None
Module: CISCO-OPTICAL-MONITOR-MIB
This object indicates the maximum severity of any thresholds
that are currently being exceeded on the interface, for the
optical parameter.
cOpticalParamAlarmCurMaxSev OBJECT-TYPE SYNTAX OpticalAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the maximum severity of any thresholds that are currently being exceeded on the interface, for the optical parameter." ::= { cOpticalMonEntry 15 }
cOpticalParamAlarmCurMaxSev OBJECT-TYPE SYNTAX OpticalAlarmSeverity ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the maximum severity of any thresholds that are currently being exceeded on the interface, for the optical parameter." ::= { cOpticalMonEntry 15 }
Vendor: Cisco
Module: CISCO-OPTICAL-MONITOR-MIB
[Automatically extracted from oidview.com]
cOpticalParamAlarmCurMaxSev OBJECT-TYPE SYNTAX OpticalAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the maximum severity of any thresholds that are currently being exceeded on the interface, for the optical parameter." ::= { cOpticalMonEntry 15 }
cOpticalParamAlarmCurMaxSev OBJECT-TYPE SYNTAX OpticalAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the maximum severity of any thresholds that are currently being exceeded on the interface, for the optical parameter." ::= { cOpticalMonEntry 15 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.264.1.1.1.1.1 | cOpticalMonDirection | 0 | 0 | This object indicates the direction monitored for the optical interface, in this entry. |
1.3.6.1.4.1.9.9.264.1.1.1.1.2 | cOpticalMonLocation | 0 | 0 | This object indicates whether the optical characteristics are measured before or after adjustment (e.g. optical amplification or … |
1.3.6.1.4.1.9.9.264.1.1.1.1.3 | cOpticalMonParameterType | 0 | 0 | This object specifies the optical parameter that is being monitored in this entry. |
1.3.6.1.4.1.9.9.264.1.1.1.1.4 | cOpticalParameterValue | 0 | 0 | This object gives the value measured for the particular optical parameter specified by the cOpticalMonParameterType object. |
1.3.6.1.4.1.9.9.264.1.1.1.1.5 | cOpticalParamHighAlarmThresh | 0 | 0 | This object is used to set a high alarm threshold on the optical parameter being monitored. An alarm condition will be raised if … |
1.3.6.1.4.1.9.9.264.1.1.1.1.6 | cOpticalParamHighAlarmSev | 0 | 0 | This object is used to specify a severity level associated with the high alarm threshold given by the cOpticalParamHighAlarmThres… |
1.3.6.1.4.1.9.9.264.1.1.1.1.7 | cOpticalParamHighWarningThresh | 0 | 0 | This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will… |
1.3.6.1.4.1.9.9.264.1.1.1.1.8 | cOpticalParamHighWarningSev | 0 | 0 | This object is used to specify a severity level associated with the high warning threshold given by the cOpticalParamHighWarningT… |
1.3.6.1.4.1.9.9.264.1.1.1.1.9 | cOpticalParamLowAlarmThresh | 0 | 0 | This object is used to set a low alarm threshold on the optical parameter being monitored. An alarm condition will be raised if t… |
1.3.6.1.4.1.9.9.264.1.1.1.1.10 | cOpticalParamLowAlarmSev | 0 | 0 | This object is used to specify a severity level associated with the low alarm threshold given by the cOpticalParamLowAlarmThresh … |
1.3.6.1.4.1.9.9.264.1.1.1.1.11 | cOpticalParamLowWarningThresh | 0 | 0 | This object is used to set a low warning threshold on the optical parameter being monitored. A threshold crossing condition will … |
1.3.6.1.4.1.9.9.264.1.1.1.1.12 | cOpticalParamLowWarningSev | 0 | 0 | This object is used to specify a severity level associated with the low warning threshold given by the cOpticalParamLowWarningThr… |
1.3.6.1.4.1.9.9.264.1.1.1.1.13 | cOpticalParamAlarmStatus | 0 | 0 | This object is used to indicate the current status of the thresholds for the monitored optical parameter on the interface. If a th… |
1.3.6.1.4.1.9.9.264.1.1.1.1.14 | cOpticalParamAlarmCurMaxThresh | 0 | 0 | This object indicates the threshold value of the highest severity threshold that is currently being exceeded on the interface, fo… |
1.3.6.1.4.1.9.9.264.1.1.1.1.16 | cOpticalParamAlarmLastChange | 0 | 0 | This object specifies the value of sysUpTime at the last time a threshold related to a particular optical parameter was exceeded … |
1.3.6.1.4.1.9.9.264.1.1.1.1.17 | cOpticalMon15MinValidIntervals | 0 | 0 | This object gives the number of previous 15 minute intervals for which valid performance monitoring data has been stored on the i… |
1.3.6.1.4.1.9.9.264.1.1.1.1.18 | cOpticalMon24HrValidIntervals | 0 | 0 | This object gives the number of previous 24 hour intervals for which valid performance monitoring data has been stored on the int… |
1.3.6.1.4.1.9.9.264.1.1.1.1.19 | cOpticalParamThreshSource | 0 | 0 | This object indicates if the current value of a particular threshold in this entry is user configured value or it is a system def… |