An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex.
Parsed from file CISCO-FABRIC-C12K-MIB.mib
Module: CISCO-FABRIC-C12K-MIB
An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex.
An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex.
Parsed from file CISCO-FABRIC-C12K-MIB.my.txt
Company: None
Module: CISCO-FABRIC-C12K-MIB
An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex.
cfcOc192FabToFabEntry OBJECT-TYPE SYNTAX CfcOc192FabToFabEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry providing various statistics and information of OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex." INDEX { entPhysicalIndex } ::= { cfcOc192FabToFabTable 1 }
cfcOc192FabToFabEntry OBJECT-TYPE SYNTAX CfcOc192FabToFabEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry providing various statistics and information of OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex." INDEX { entPhysicalIndex } ::= { cfcOc192FabToFabTable 1 }
Vendor: Cisco
Module: CISCO-FABRIC-C12K-MIB
[Automatically extracted from oidview.com]
cfcOc192FabToFabEntry OBJECT-TYPE SYNTAX CfcOc192FabToFabEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry providing various statistics and information of OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex." INDEX { entPhysicalIndex } ::= { cfcOc192FabToFabTable 1 }
cfcOc192FabToFabEntry OBJECT-TYPE SYNTAX CfcOc192FabToFabEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry providing various statistics and information of OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex." INDEX { entPhysicalIndex } ::= { cfcOc192FabToFabTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.281.1.3.1.1.1.1 | cfcOc192FabToFabMccDataPEs | 0 | 0 | Count of the parity errors on data lines from MCC to ToFabFIA. This error would cause the ToFabFIA to halt. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.2 | cfcOc192FabToFabMccCmdPEs | 0 | 0 | Count of the parity errors on command lines from MCC to ToFabFIA. This error would cause the ToFabFIA to halt. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.3 | cfcOc192FabToFabBackPressurePEs | 0 | 0 | Count of the parity errors on back pressure line from FrFabFIA to ToFabFIA. This error would cause the ToFabFIA to halt. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.4 | cfcOc192FabToFabCellFifoOvFlws | 0 | 0 | Count of the cell fifo overflow errors detected by the ToFabFIA. This error would cause the ToFabFIA to halt. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.5 | cfcOc192FabToFabCellFifoUnFlws | 0 | 0 | Count of the cell fifo underflow errors detected by the ToFabFIA. This error would cause the ToFabFIA to halt. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.6 | cfcOc192FabToFabMccCmdSeqEndErrs | 0 | 0 | Count of the illegal sequence of command errors where a middle or start command followed by a start command is received from MCC. |
1.3.6.1.4.1.9.9.281.1.3.1.1.1.7 | cfcOc192FabToFabMccCmdSeqStrErrs | 0 | 0 | Count of the illegal sequence of command errors where an end command followed by an end or middle command is received from MCC. |