This object specifies the domain number used to create logical
group of PTP devices.
Parsed from file CISCO-PTP-MIB.mib
Module: CISCO-PTP-MIB
This object specifies the domain number used to create logical
group of PTP devices.
This object specifies the domain number used to create logical
group of PTP devices.
Parsed from file CISCO-PTP-MIB.my.txt
Company: None
Module: CISCO-PTP-MIB
This object specifies the domain number used to create logical
group of PTP devices.
cPtpClockDomainIndex OBJECT-TYPE SYNTAX ClockDomainType MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockNodeEntry 1 }
cPtpClockDomainIndex OBJECT-TYPE SYNTAX ClockDomainType ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockNodeEntry 1 }
Vendor: Cisco
Module: CISCO-PTP-MIB
[Automatically extracted from oidview.com]
cPtpClockDomainIndex OBJECT-TYPE SYNTAX ClockDomainType MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockNodeEntry 1 }
cPtpClockDomainIndex OBJECT-TYPE SYNTAX ClockDomainType MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the domain number used to create logical group of PTP devices." ::= { cPtpClockNodeEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.760.1.1.3.1.2 | cPtpClockTypeIndex | 0 | 0 | This object specifies the clock type as defined in the Textual convention description. |
1.3.6.1.4.1.9.9.760.1.1.3.1.3 | cPtpClockInstanceIndex | 0 | 0 | This object specifies the instance of the Clock for this clock type for the given domain. |
1.3.6.1.4.1.9.9.760.1.1.3.1.4 | cPtpClockInput1ppsEnabled | 0 | 0 | This object specifies whether the node is enabled for PTP input clocking using the 1pps interface. |
1.3.6.1.4.1.9.9.760.1.1.3.1.5 | cPtpClockInputFrequencyEnabled | 0 | 0 | This object specifies whether enabled for Frequency input using the 1.544 Mhz, 2.048 Mhz, or 10Mhz timing interface. |
1.3.6.1.4.1.9.9.760.1.1.3.1.6 | cPtpClockTODEnabled | 0 | 0 | This object specifies whether the node is enabled for TOD. |
1.3.6.1.4.1.9.9.760.1.1.3.1.7 | cPtpClockOutput1ppsEnabled | 0 | 0 | This object specifies whether the node is enabled for PTP input clocking using the 1pps interface. |
1.3.6.1.4.1.9.9.760.1.1.3.1.8 | cPtpClockOutput1ppsOffsetEnabled | 0 | 0 | This object specifies whether an offset is configured in order to compensate for a known phase error such as network asymmetry. |
1.3.6.1.4.1.9.9.760.1.1.3.1.9 | cPtpClockOutput1ppsOffsetValue | 0 | 0 | This object specifies the fixed offset value configured to be added for the 1pps output. |
1.3.6.1.4.1.9.9.760.1.1.3.1.10 | cPtpClockOutput1ppsOffsetNegative | 0 | 0 | This object specifies whether the added (fixed) offset to the 1pps output is negative or not. When object returns TRUE the offse… |
1.3.6.1.4.1.9.9.760.1.1.3.1.11 | cPtpClockInput1ppsInterface | 0 | 0 | This object specifies the 1pps interface used for PTP input clocking. |
1.3.6.1.4.1.9.9.760.1.1.3.1.12 | cPtpClockOutput1ppsInterface | 0 | 0 | This object specifies the 1pps interface used for PTP output clocking. |
1.3.6.1.4.1.9.9.760.1.1.3.1.13 | cPtpClockTODInterface | 0 | 0 | This object specifies the interface used for PTP TOD. |