An entry in the table, containing information about a single
clock port.
Parsed from file CISCO-PTP-MIB.mib
Module: CISCO-PTP-MIB
An entry in the table, containing information about a single
clock port.
An entry in the table, containing information about a single
clock port.
Parsed from file CISCO-PTP-MIB.my.txt
Company: None
Module: CISCO-PTP-MIB
An entry in the table, containing information about a single
clock port.
cPtpClockPortEntry OBJECT-TYPE SYNTAX CPtpClockPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single clock port." INDEX { cPtpClockPortDomainIndex, cPtpClockPortClockTypeIndex, cPtpClockPortClockInstanceIndex, cPtpClockPortTablePortNumberIndex } ::= { cPtpClockPortTable 1 }
cPtpClockPortEntry OBJECT-TYPE SYNTAX CPtpClockPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single clock port." INDEX { cPtpClockPortDomainIndex, cPtpClockPortClockTypeIndex, cPtpClockPortClockInstanceIndex, cPtpClockPortTablePortNumberIndex } ::= { cPtpClockPortTable 1 }
Vendor: Cisco
Module: CISCO-PTP-MIB
[Automatically extracted from oidview.com]
cPtpClockPortEntry OBJECT-TYPE SYNTAX CPtpClockPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single clock port." INDEX { cPtpClockPortDomainIndex, cPtpClockPortClockTypeIndex, cPtpClockPortClockInstanceIndex, cPtpClockPortTablePortNumberIndex } ::= { cPtpClockPortTable 1 }
cPtpClockPortEntry OBJECT-TYPE SYNTAX CPtpClockPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table, containing information about a single clock port." INDEX { cPtpClockPortDomainIndex, cPtpClockPortClockTypeIndex, cPtpClockPortClockInstanceIndex, cPtpClockPortTablePortNumberIndex } ::= { cPtpClockPortTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.760.1.2.7.1.1 | cPtpClockPortDomainIndex | 0 | 0 | This object specifies the domain number used to create logical group of PTP devices. |
1.3.6.1.4.1.9.9.760.1.2.7.1.2 | cPtpClockPortClockTypeIndex | 0 | 0 | This object specifies the clock type as defined in the Textual convention description. |
1.3.6.1.4.1.9.9.760.1.2.7.1.3 | cPtpClockPortClockInstanceIndex | 0 | 0 | This object specifies the instance of the clock for this clock type in the given domain. |
1.3.6.1.4.1.9.9.760.1.2.7.1.4 | cPtpClockPortTablePortNumberIndex | 0 | 0 | This object specifies the PTP Portnumber for this port. |
1.3.6.1.4.1.9.9.760.1.2.7.1.5 | cPtpClockPortName | 0 | 0 | This object specifies the PTP clock port name configured on the router. |
1.3.6.1.4.1.9.9.760.1.2.7.1.6 | cPtpClockPortRole | 0 | 0 | This object describes the current role (slave/master) of the port. |
1.3.6.1.4.1.9.9.760.1.2.7.1.7 | cPtpClockPortSyncOneStep | 0 | 0 | This object specifies that one-step clock operation between the PTP master and slave device is enabled. |
1.3.6.1.4.1.9.9.760.1.2.7.1.8 | cPtpClockPortCurrentPeerAddressType | 0 | 0 | This object specifies the current peer's network address used for PTP communication. Based on the scenario and the setup involved… |
1.3.6.1.4.1.9.9.760.1.2.7.1.9 | cPtpClockPortCurrentPeerAddress | 0 | 0 | This object specifies the current peer's network address used for PTP communication. Based on the scenario and the setup involved… |
1.3.6.1.4.1.9.9.760.1.2.7.1.10 | cPtpClockPortNumOfAssociatedPorts | 0 | 0 | This object specifies - For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave po… |