This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority.
Parsed from file CISCO-NETSYNC-MIB.mib
Module: CISCO-NETSYNC-MIB
This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority.
This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority.
Parsed from file CISCO-NETSYNC-MIB.my.txt
Company: None
Module: CISCO-NETSYNC-MIB
This object indicates the configured
priority of the selected T0 clock.
A smaller value represents a higher priority.
cnsSelInpSrcPriority OBJECT-TYPE SYNTAX Unsigned32 (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configured priority of the selected T0 clock. A smaller value represents a higher priority." REFERENCE "ITU-T standard G.781 section 5.10" ::= { cnsSelectedInputSourceEntry 5 }
cnsSelInpSrcPriority OBJECT-TYPE SYNTAX Gauge(1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the configured priority of the selected T0 clock. A smaller value represents a higher priority." REFERENCE "ITU-T standard G.781 section 5.10" ::= { cnsSelectedInputSourceEntry 5 }
Vendor: Cisco
Module: CISCO-NETSYNC-MIB
[Automatically extracted from oidview.com]
cnsSelInpSrcPriority OBJECT-TYPE SYNTAX Unsigned32 (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configured priority of the selected T0 clock. A smaller value represents a higher priority." REFERENCE "ITU-T standard G.781 section 5.10" ::= { cnsSelectedInputSourceEntry 5 }
cnsSelInpSrcPriority OBJECT-TYPE SYNTAX Unsigned32 (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configured priority of the selected T0 clock. A smaller value represents a higher priority." REFERENCE "ITU-T standard G.781 section 5.10" ::= { cnsSelectedInputSourceEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.761.1.1.2.1.1 | cnsSelInpSrcNetsyncIndex | 0 | 0 | An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and m… |
1.3.6.1.4.1.9.9.761.1.1.2.1.2 | cnsSelInpSrcName | 0 | 0 | This object indicates the name of the selected T0 clock. |
1.3.6.1.4.1.9.9.761.1.1.2.1.3 | cnsSelInpSrcIntfType | 0 | 0 | cnsSelInpSrcIntftype |
1.3.6.1.4.1.9.9.761.1.1.2.1.4 | cnsSelInpSrcQualityLevel | 0 | 0 | This object indicates the selected T0 clock source's effective quality level, which is the derived clock quality based on the thr… |
1.3.6.1.4.1.9.9.761.1.1.2.1.6 | cnsSelInpSrcTimestamp | 0 | 0 | This object indicates the timestamp of the T0 clock source being selected by the G.781 clock selection process. |
1.3.6.1.4.1.9.9.761.1.1.2.1.7 | cnsSelInpSrcFSW | 0 | 0 | This object indicates the forced switching flag. Forced switching, as described in G.781, is used to override the currently selec… |
1.3.6.1.4.1.9.9.761.1.1.2.1.8 | cnsSelInpSrcMSW | 0 | 0 | This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of th… |