Reference record for OID 1.3.6.1.4.1.9.9.761.1.1.3.1.12



parent
1.3.6.1.4.1.9.9.761.1.1.3.1 (cnsInputSourceEntry)
node code
12
node name
cnsInpSrcHoldoffTime
dot oid
1.3.6.1.4.1.9.9.761.1.1.3.1.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoNetsyncMIB(761) ciscoNetsyncMIBObjects(1) ciscoNetsyncMIBTables(1) cnsInputSourceTable(3) cnsInputSourceEntry(1) cnsInpSrcHoldoffTime(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • /iso/iso-identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoNetsyncMIB/ciscoNetsyncMIBObjects/ciscoNetsyncMIBTables/cnsInputSourceTable/cnsInputSourceEntry/cnsInpSrcHoldoffTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/9/9/761/1/1/3/1/12

    Description by circitor

    This object indicates the hold-off time value of
    an input clock source.

    The hold-off time prevents short activation of signal failure
    is passed to the selection process. When a signal failure
    event is reported on a clock source, it waits the duration of
    the hold-off time before declaring signal failure on the clock
    source.

    Parsed from file CISCO-NETSYNC-MIB.mib
    Module: CISCO-NETSYNC-MIB

    Description by cisco_v1

    This object indicates the hold-off time value of
    an input clock source.

    The hold-off time prevents short activation of signal failure
    is passed to the selection process. When a signal failure
    event is reported on a clock source, it waits the duration of
    the hold-off time before declaring signal failure on the clock
    source.

    Description by oid_info

    cnsInpSrcHoldofftime
    View at oid-info.com

    Description by mibdepot

    This object indicates the hold-off time value of
    an input clock source.

    The hold-off time prevents short activation of signal failure
    is passed to the selection process. When a signal failure
    event is reported on a clock source, it waits the duration of
    the hold-off time before declaring signal failure on the clock
    source.

    Parsed from file CISCO-NETSYNC-MIB.my.txt
    Company: None
    Module: CISCO-NETSYNC-MIB

    Description by cisco

    This object indicates the hold-off time value of
    an input clock source.

    The hold-off time prevents short activation of signal failure
    is passed to the selection process. When a signal failure
    event is reported on a clock source, it waits the duration of
    the hold-off time before declaring signal failure on the clock
    source.

    Information by circitor

    cnsInpSrcHoldoffTime OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the hold-off time value of an input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration of the hold-off time before declaring signal failure on the clock source." REFERENCE "ITU-T standard G.781 section 5.8" ::= { cnsInputSourceEntry 12 }

    Information by cisco_v1

    cnsInpSrcHoldoffTime OBJECT-TYPE SYNTAX Gauge(0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the hold-off time value of an input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration of the hold-off time before declaring signal failure on the clock source." REFERENCE "ITU-T standard G.781 section 5.8" ::= { cnsInputSourceEntry 12 }

    Information by oid_info

    Vendor: Cisco
    Module: CISCO-NETSYNC-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cnsInpSrcHoldoffTime OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the hold-off time value of an input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration of the hold-off time before declaring signal failure on the clock source." REFERENCE "ITU-T standard G.781 section 5.8" ::= { cnsInputSourceEntry 12 }

    Information by cisco

    cnsInpSrcHoldoffTime OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the hold-off time value of an input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration of the hold-off time before declaring signal failure on the clock source." REFERENCE "ITU-T standard G.781 section 5.8" ::= { cnsInputSourceEntry 12 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Greg Satz

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Cisco Systems, Inc.

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.761.1.1.3.1.1 cnsInpSrcNetsyncIndex 0 0 An index that uniquely represents an entry in
    this table. This index is assigned arbitrarily
    by the clock selection process and m…
    1.3.6.1.4.1.9.9.761.1.1.3.1.2 cnsInpSrcName 0 0 This object indicates the name of an input
    clock source configured for the T0 clock
    selection.
    1.3.6.1.4.1.9.9.761.1.1.3.1.3 cnsInpSrcIntfType 0 0 cnsInpSrcIntftype
    1.3.6.1.4.1.9.9.761.1.1.3.1.4 cnsInpSrcPriority 0 0 This object indicates the priority of an input
    clock source configured for the T0 clock
    selection.

    A smaller value represents a h…
    1.3.6.1.4.1.9.9.761.1.1.3.1.5 cnsInpSrcESMCCap 0 0 This object indicates the ESMC capability
    of an input clock source configured for the
    T0 clock selection. This is applicable onl…
    1.3.6.1.4.1.9.9.761.1.1.3.1.6 cnsInpSrcSSMCap 0 0 This object indicates the SSM capability
    of an input clock source configured for the
    T0 clock selection. This is applicable only …
    1.3.6.1.4.1.9.9.761.1.1.3.1.7 cnsInpSrcQualityLevelTxCfg 0 0 This object indicates the configured transmit
    clock quality level of an input clock source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.8 cnsInpSrcQualityLevelRxCfg 0 0 This object indicates the configured receive
    clock quality level of an input clock source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.9 cnsInpSrcQualityLevelTx 0 0 This object indicates the most recent clock
    quality level transmitted on the input clock
    source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.10 cnsInpSrcQualityLevelRx 0 0 This object indicates the last clock quality
    level received on the input clock source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.11 cnsInpSrcQualityLevel 0 0 This object indicates the current clock quality
    level of the input clock source. This is the
    effective quality which is derived …
    1.3.6.1.4.1.9.9.761.1.1.3.1.13 cnsInpSrcWtrTime 0 0 This object indicates the wait-to-restore time value
    of an input clock source.

    The wait-to-restore time ensures that a previous …
    1.3.6.1.4.1.9.9.761.1.1.3.1.14 cnsInpSrcLockout 0 0 This object indicates whether or not the lockout
    command has been applied to a clock source.

    The 'true' value means the clock so…
    1.3.6.1.4.1.9.9.761.1.1.3.1.15 cnsInpSrcSignalFailure 0 0 This object indicates whether or not a
    signal failure event is currently being
    reported on the input clock source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.16 cnsInpSrcAlarm 0 0 This object indicates whether or not an
    alarm event is currently being reported
    on the input clock source.
    1.3.6.1.4.1.9.9.761.1.1.3.1.17 cnsInpSrcAlarmInfo 0 0 This object indicates the alarm reasons of
    an input clock source if an alarm event
    is being reported on it.
    1.3.6.1.4.1.9.9.761.1.1.3.1.18 cnsInpSrcFSW 0 0 This object indicates the forced switching flag.
    Forced switching, as described in G.781, is used to
    override the currently selec…
    1.3.6.1.4.1.9.9.761.1.1.3.1.19 cnsInpSrcMSW 0 0 This object indicates the manual switching flag.

    The 'true' value indicates the currently selected clock source
    is a result of t…