caReportNokiaAlarmTraps OBJECT-TYPE
SYNTAX EnabledDisabled
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This NE wide variable is used to control if the NE reports alarms
using Nokia Common Alarm syntax. When the value equals to enabled,
the NE shall report alarms using Nokia Common Alarm Traps, and when
disabled, Nokia Common Alarm Traps shall not be emitted.
The default value for this variable is enabled."
View at oid-info.com
This NE wide variable is used to control if the NE reports alarms
using Nokia Common Alarm syntax. When the value equals to enabled,
the NE shall report alarms using Nokia Common Alarm Traps, and when
disabled, Nokia Common Alarm Traps shall not be emitted.
The default value for this variable is enabled.
Parsed from file NOKIA-COMMON-ALARM-REPORTING-MIB.my.txt
Company: None
Module: NOKIA-COMMON-ALARM-REPORTING-MIB
This NE wide variable is used to control if the NE reports alarms
using Nokia Common Alarm syntax. When the value equals to enabled,
the NE shall report alarms using Nokia Common Alarm Traps, and when
disabled, Nokia Common Alarm Traps shall not be emitted.
The default value for this variable is enabled.
Parsed from file NOKIA-COMMON-ALARM-REPORTING-MIB.mib
Module: NOKIA-COMMON-ALARM-REPORTING-MIB
Automatically extracted from a module checked by a user of the Asnp syntax-checking tool
caReportNokiaAlarmTraps OBJECT-TYPE SYNTAX EnabledDisabled ACCESS read-write STATUS mandatory DESCRIPTION "This NE wide variable is used to control if the NE reports alarms using Nokia Common Alarm syntax. When the value equals to enabled, the NE shall report alarms using Nokia Common Alarm Traps, and when disabled, Nokia Common Alarm Traps shall not be emitted. The default value for this variable is enabled." ::= {caVars 1}
caReportNokiaAlarmTraps OBJECT-TYPE SYNTAX EnabledDisabled ACCESS read-write STATUS mandatory DESCRIPTION "This NE wide variable is used to control if the NE reports alarms using Nokia Common Alarm syntax. When the value equals to enabled, the NE shall report alarms using Nokia Common Alarm Traps, and when disabled, Nokia Common Alarm Traps shall not be emitted. The default value for this variable is enabled." ::= {caVars 1}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.94.1.16.1.1.1.1.0 | caReportNokiaAlarmTraps | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.94.1.16.1.1.1.2 | caReportLinkUpLinkDownTraps | 1 | 1 | This NE wide variable is used to control if the NE reports standard linkUp and linkDown traps. When the value equals to enabled,… |
1.3.6.1.4.1.94.1.16.1.1.1.3 | caAlarmText | 1 | 1 | Alarm text of the last Nokia enterprise specific alarm trap emitted by the NE. This is textual description shown e.g. on user int… |
1.3.6.1.4.1.94.1.16.1.1.1.4 | caTrapId | 1 | 1 | caTrapId of the last Nokia enterprise specific alarm trap emitted by the NE. caTrapId shall be incremented by one in each trap se… |
1.3.6.1.4.1.94.1.16.1.1.1.5 | caCorrelatedAlarmId | 1 | 1 | This variable shall be supported by an NE product if support for real-time current alarm list in NMS is expected. When supported… |
1.3.6.1.4.1.94.1.16.1.1.1.6 | caColumnInTbl | 1 | 1 | The value of caColumnInTbl field of the last Nokia enterprise specific alarm trap emitted by the NE. The value is the name of the… |
1.3.6.1.4.1.94.1.16.1.1.1.7 | caRowIdx | 1 | 1 | This variable contains value {0 0} for the time being. When this object is accessed using GET operation, this object shall conta… |
1.3.6.1.4.1.94.1.16.1.1.1.8 | caSeverity | 1 | 1 | Severity of the last Nokia enterprise specific alarm trap emitted by the NE. When this object is accessed using GET operation, th… |
1.3.6.1.4.1.94.1.16.1.1.1.9 | caNESpecificAlarmManualPageNbr | 1 | 1 | caNESpecificAlarmManualPageNbr of the last Nokia enterprise specific alarm trap emitted by the NE. The value is the alarm manual… |
1.3.6.1.4.1.94.1.16.1.1.1.10 | caSupplementaryInfo | 1 | 1 | Supplementary information fields of the last Nokia enterprise specific alarm trap emitted by the NE. Alarm manual page contains t… |