Reference record for OID 0.4.0.304.0.7.20

Parent
0.4.0.304.0.7 (etsAttribute)
Node code
20
Node name
syncProtectionStatus
Numeric OID
0.4.0.304.0.7.20
URN notation
urn:oid:0.4.0.304.0.7.20
ASN.1 notation

{0 4 0 304 0 7 20}

  • {itu-t(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
  • {itu-t(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
  • {itu-t(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
  • {ccitt(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
  • {ccitt(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
  • {ccitt(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsAttribute(7) syncProtectionStatus(20)}
OID-IRI notation
  • /0/4/0/304/0/7/20
  • /ITU-T/Identified-Organization/0/304/0/7/20
  • /ITU-T/4/0/304/0/7/20
Named path variants
  • /itu-t/identified-organization/etsi/304/prETS300304/etsAttribute/syncProtectionStatus
  • /itu-t/identified-organization/oidETSI/304/prETS300304/etsAttribute/syncProtectionStatus
  • /itu-t/identified-organization/etsiPrefix/304/prETS300304/etsAttribute/syncProtectionStatus
  • /ccitt/identified-organization/etsi/304/prETS300304/etsAttribute/syncProtectionStatus
  • /ccitt/identified-organization/oidETSI/304/prETS300304/etsAttribute/syncProtectionStatus
  • /ccitt/identified-organization/etsiPrefix/304/prETS300304/etsAttribute/syncProtectionStatus

Descriptions

syncProtectionStatus — ETSI published formal attachments

This attribute is used to indicate the status of the protection switch in a protectionUnit instance. The remainder of this behaviour provides the allowable syncProtectionStatus attribute values for protecting units. No Request: No request is present on the protecting unit. Manual Switch Complete to Protecting Unit: A Manual Switch has been completed to this protecting unit. Force Switch Complete to Protecting Unit: A Force Switch has been completed to this protecting unit. Automatic Switch Complete to Protecting Unit: An Automatic Switch has been completed to this protecting unit. Protecting Unit Failed: The protecting unit has a failure condition present. Protecting Unit Locked Out: The protecting unit has been locked out.

Source records

syncProtectionStatus

Status in source: unspecified.

Names: syncProtectionStatus

Technical details
{
  "gdmo_kind": "ATTRIBUTE",
  "definition": [
    "syncProtectionStatus",
    "ATTRIBUTE",
    "WITH",
    "ATTRIBUTE",
    "SYNTAX",
    "PrETS13",
    ".",
    "SyncProtectionStatus",
    ";",
    "MATCHES",
    "FOR",
    "EQUALITY",
    ",",
    "SET-COMPARISON",
    ",",
    "SET-INTERSECTION",
    ";",
    "BEHAVIOUR",
    "syncProtectionStatusBeh",
    ";",
    "REGISTERED",
    "AS",
    "{",
    "etsAttribute",
    "20",
    "}",
    ";"
  ]
}

Current Registration Authority (inferred from ancestor 0.4.0)

Anthony Wiles

Siblings (21)

OIDNameDirect childrenDescendantsDescription
0.4.0.304.0.7.1 p12CTPId00
0.4.0.304.0.7.2 p31CTPId00
0.4.0.304.0.7.3 p4CTPId00
0.4.0.304.0.7.4 equipmentActual00
0.4.0.304.0.7.5 equipmentExpected00
0.4.0.304.0.7.6 specificPhysicalInstance00
0.4.0.304.0.7.7 physicalConnectorList00
0.4.0.304.0.7.8 powerSupplyId00
0.4.0.304.0.7.9 powerSource00
0.4.0.304.0.7.10 currentTimingSourcePointer00
0.4.0.304.0.7.11 poweredEquipmentPtrList00
0.4.0.304.0.7.12 equipmentProtectionStatus00
0.4.0.304.0.7.13 protectionUnitPointer00
0.4.0.304.0.7.14 outputTimingSourcePointer00
0.4.0.304.0.7.15 sSMActive00
0.4.0.304.0.7.16 sSMQuality00
0.4.0.304.0.7.17 squelchStatus00
0.4.0.304.0.7.18 squelchT0Threshold00
0.4.0.304.0.7.19 squelchT1Threshold00
0.4.0.304.0.7.21 timingPhysicalTerminationId00
0.4.0.304.0.7.22 timingGeneratorId00