Reference record for OID 0.4.0.304.0.7.4

Parent
0.4.0.304.0.7 (etsAttribute)
Node code
4
Node name
equipmentActual
Numeric OID
0.4.0.304.0.7.4
URN notation
urn:oid:0.4.0.304.0.7.4
ASN.1 notation

{0 4 0 304 0 7 4}

  • {itu-t(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
  • {itu-t(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
  • {itu-t(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
  • {ccitt(0) identified-organization(4) etsi(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
  • {ccitt(0) identified-organization(4) oidETSI(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
  • {ccitt(0) identified-organization(4) etsiPrefix(0) 304 prETS300304(0) etsAttribute(7) equipmentActual(4)}
OID-IRI notation
  • /0/4/0/304/0/7/4
  • /ITU-T/Identified-Organization/0/304/0/7/4
  • /ITU-T/4/0/304/0/7/4
Named path variants
  • /itu-t/identified-organization/etsi/304/prETS300304/etsAttribute/equipmentActual
  • /itu-t/identified-organization/oidETSI/304/prETS300304/etsAttribute/equipmentActual
  • /itu-t/identified-organization/etsiPrefix/304/prETS300304/etsAttribute/equipmentActual
  • /ccitt/identified-organization/etsi/304/prETS300304/etsAttribute/equipmentActual
  • /ccitt/identified-organization/oidETSI/304/prETS300304/etsAttribute/equipmentActual
  • /ccitt/identified-organization/etsiPrefix/304/prETS300304/etsAttribute/equipmentActual

Descriptions

equipmentActual — ETSI published formal attachments

This attribute is used to indicate the status of the protection switch in a protectionUnit instance. The remainder of this behaviour provides the allowable equipmentProtectionStatus attribute values for protected and protecting units for both revertive and non-revertive systems. The following allowable equipmentProtectionStatus values are associated with each protected unit: No Request: No switch request is present on the unit. Manual Switch to Protecting Complete: The unit has completed a Manual Switch. Automatic Switch Pending: The unit has a failure condition present and the protecting unit is unavailable. Automatic Switch Complete: The unit has completed an Automatic Switch to the protecting unit due to failure condition. Force Switch Complete, Automatic Switch Pending: The unit has completed a Force Switch. Additionally, the unit has an automatic switch pending. Automatic Switch Complete, Wait-to-Restore: The unit has completed an Automatic Switch to the protecting unit. (revertive case only) Force Switch Complete: The unit has completed a Force Switch to the protecting unit. Protected Unit Lockout Completed: The unit has been locked out from the protecting unit. Additionally the non-revertive protected protection unit has the following status values: Do Not Revert: The protected unit has been switched to the protecting unit and the request to do so has been released. The switch to the protecting unit is maintained. The following allowable protectionStatus values are associated with each protecting unit: No Request: No request is present on the protecting unit. Manual Switch to Protecting Unit Complete: The protected unit has completed a Manual Switch. Automatic Switch Complete to Protecting Unit: The protected unit has completed an automatic switch to the protecting unit. Automatic Switch Complete to Protecting Unit, Wait to Restore: The unit has completed an Automatic Switch to the protecting unit. (revertive case only) Protecting Unit Failed: The protecting unit has a failure condition present. Force Switch Complete to Protecting Unit: The unit has completed a Force Switch of a protected unit to the protecting unit. Protecting Unit Locked Out: The protecting unit has been locked out. Additionally, the non-revertive protecting unit has the following values: Do Not Revert: The protected unit has been switched to the protecting unit and the request to do so has been released. The switch to the protecting unit is maintained. Manual Switch to Protected Unit Complete: The unit has completed a Manual Switch from the protecting unit to the protected unit.

Source records

equipmentActual

Status in source: unspecified.

Names: equipmentActual

Technical details
{
  "gdmo_kind": "ATTRIBUTE",
  "definition": [
    "equipmentActual",
    "ATTRIBUTE",
    "WITH",
    "ATTRIBUTE",
    "SYNTAX",
    "PrETS12",
    ".",
    "EquipmentActual",
    ";",
    "BEHAVIOUR",
    "equipmentActualBehaviour",
    "BEHAVIOUR",
    "DEFINED",
    "AS",
    "This",
    "attribute",
    "contains",
    "the",
    "equipment",
    "type",
    "of",
    "the",
    "equipment",
    "actually",
    "present",
    ".",
    "The",
    [
      "literal",
      "2245717569706d656e745479706522"
    ],
    "value",
    "is",
    "a",
    "vendor-specific",
    "identification",
    "of",
    "a",
    "particular",
    "set",
    "or",
    "class",
    "of",
    "equipment",
    ",",
    "where",
    "all",
    "the",
    "set",
    "members",
    "have",
    "equivalent",
    "capability",
    ".",
    ";",
    ";",
    "REGISTERED",
    "AS",
    "{",
    "etsAttribute",
    "4",
    "}",
    ";"
  ]
}

Current Registration Authority (inferred from ancestor 0.4.0)

Anthony Wiles

Siblings (21)

OIDNameDirect childrenDescendantsDescription
0.4.0.304.0.7.1 p12CTPId00
0.4.0.304.0.7.2 p31CTPId00
0.4.0.304.0.7.3 p4CTPId00
0.4.0.304.0.7.5 equipmentExpected00
0.4.0.304.0.7.6 specificPhysicalInstance00
0.4.0.304.0.7.7 physicalConnectorList00
0.4.0.304.0.7.8 powerSupplyId00
0.4.0.304.0.7.9 powerSource00
0.4.0.304.0.7.10 currentTimingSourcePointer00
0.4.0.304.0.7.11 poweredEquipmentPtrList00
0.4.0.304.0.7.12 equipmentProtectionStatus00
0.4.0.304.0.7.13 protectionUnitPointer00
0.4.0.304.0.7.14 outputTimingSourcePointer00
0.4.0.304.0.7.15 sSMActive00
0.4.0.304.0.7.16 sSMQuality00
0.4.0.304.0.7.17 squelchStatus00
0.4.0.304.0.7.18 squelchT0Threshold00
0.4.0.304.0.7.19 squelchT1Threshold00
0.4.0.304.0.7.20 syncProtectionStatus00
0.4.0.304.0.7.21 timingPhysicalTerminationId00
0.4.0.304.0.7.22 timingGeneratorId00