Reference record for OID 1.0.62379.7.1.4.2.1.7

Parent
1.0.62379.7.1.4.2.1 (rxPointEntry)
Node code
7
Node name
rxPointTSDF
Numeric OID
1.0.62379.7.1.4.2.1.7
URN notation
urn:oid:1.0.62379.7.1.4.2.1.7
ASN.1 notation

{1 0 62379 7 1 4 2 1 7}

  • {iso(1) standard(0) iec62379(62379) measurement(7) measurementMIB(1) receiverMeasurement(4) rxPointTable(2) rxPointEntry(1) rxPointTSDF(7)}
  • {iso(1) std(0) iec62379(62379) measurement(7) measurementMIB(1) receiverMeasurement(4) rxPointTable(2) rxPointEntry(1) rxPointTSDF(7)}
  • {iso(1) iso-standard(0) iec62379(62379) measurement(7) measurementMIB(1) receiverMeasurement(4) rxPointTable(2) rxPointEntry(1) rxPointTSDF(7)}
  • {iso(1) oidISO(0) iec62379(62379) measurement(7) measurementMIB(1) receiverMeasurement(4) rxPointTable(2) rxPointEntry(1) rxPointTSDF(7)}
OID-IRI notation
  • /1/0/62379/7/1/4/2/1/7
  • /ISO/Standard/62379/7/1/4/2/1/7
  • /ISO/0/62379/7/1/4/2/1/7
Named path variants
  • /iso/standard/iec62379/measurement/measurementMIB/receiverMeasurement/rxPointTable/rxPointEntry/rxPointTSDF
  • /iso/std/iec62379/measurement/measurementMIB/receiverMeasurement/rxPointTable/rxPointEntry/rxPointTSDF
  • /iso/iso-standard/iec62379/measurement/measurementMIB/receiverMeasurement/rxPointTable/rxPointEntry/rxPointTSDF
  • /iso/oidISO/iec62379/measurement/measurementMIB/receiverMeasurement/rxPointTable/rxPointEntry/rxPointTSDF

Descriptions

rxPointTSDF — EBU Tech 3345 official MIB annexes (July 2011)

A description of the Time-stamped Delay Factor (TS-DF). Time-stamped Delay Factor is calculated as: TS-DF = D(Max) - D(Min) For further details of this, see EBU TECH3337

Source records

rxPointTSDF

Status in source: current.

Names: rxPointTSDF

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rxPointTSDF",
    "OBJECT-TYPE",
    "SYNTAX",
    "CardinalNumber",
    "UNITS",
    [
      "literal",
      "226d7322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"A description of the Time-stamped Delay Factor (TS-DF). Time-stamped Delay Factor is calculated as: TS-DF = D(Max) - D(Min) For further details of this, see EBU TECH3337\"",
    "::=",
    "{",
    "rxPointEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "CardinalNumber"
    ],
    [
      "UNITS",
      "ms"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "A description of the Time-stamped Delay Factor (TS-DF). Time-stamped Delay Factor is calculated as: TS-DF = D(Max) - D(Min) For further details of this, see EBU TECH3337"
    ],
    null,
    null,
    null,
    null
  ]
}
  • EBU Tech 3345 official MIB annexes (July 2011) · Publisher's source file: EBU Tech 3345 — original English PDF, July 2011 (127 pages)

    Module: IEC62379-7-IPM-MIB

    Published definition
    rxPointTSDF OBJECT-TYPE
           SYNTAX CardinalNumber
           UNITS "ms"
           MAX-ACCESS read-only
           STATUS current
           DESCRIPTION
              "A description of the Time-stamped Delay Factor (TS-DF).
              Time-stamped Delay Factor is calculated as:
              TS-DF = D(Max) - D(Min)
              For further details of this, see EBU TECH3337"
    
    
                                                  
    
                                                                                              
    
           ::= { rxPointEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TAddress', 'TruthValue'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEC62379-1-MIB': ['iec62379', 'unitPowerSource', 'psNumber', 'psType', 'psStatus', 'psChargeLevel', 'psChargeTime', 'blockId', 'blockType', 'BlockId', 'BlockType', 'CardinalNumber', 'ClockSource', 'IndexNumber', 'IntegerNumber', 'MediaFormat', 'Utf8String'], 'IEC62379-7-IPM-TC-MIB': ['NetworkType', 'TransportType', 'TemperatureStatus', 'TemperatureLocn', 'TemperatureTrend', 'AudioFECType', 'VideoFECType', 'BufferSize', 'BufferOcpncyPercent', 'BufferOcpncyTime', 'BitRateType']}

    Source data warning: Published in an informative machine-readable annex of EBU Tech 3345 (July 2011). The corresponding normative IEC 62379 clauses take precedence. Only the explicitly printed definitions are listed; parameter combinations are not generated or claimed to be exhaustively registered.

    · Download EBU Tech 3345 — Annex C: IEC62379-7-IPM-MIB (MIB export, PDF pages 53–73)

    Related source files and packages:


    Source location: IEC62379-7-IPM-MIB::rxPointTSDF.
    Source version and references

    Machine-readable MIB exported from the official PDF; original PDF available for independent verification; EBU Tech 3345, July 2011; Publisher path: files/live/sites/tech/files/shared/tech/tech3345.pdf; 37,343 bytes

    Downloaded: 2026-10-27T10:57:18.623749+00:00.

Current Registration Authority (inferred from ancestor 1.0)

ISO and IEC

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.0.62379.7.1.4.2.1.1 rxPointBlockId00
1.0.62379.7.1.4.2.1.2 rxPointNetworkBlockId00
1.0.62379.7.1.4.2.1.3 rxPointBufferSize00
1.0.62379.7.1.4.2.1.4 rxPointBufferOcpancyTime00
1.0.62379.7.1.4.2.1.5 rxPointBufferOcpncyPcnt00
1.0.62379.7.1.4.2.1.6 rxPointMDI00