ieee8021CnPortPriLldpInstanceChoice

1.0.8802.1.1.18.1.4.1.7

Description

Specifies how to determine the LLDP instance to be used for the Congestion Notification TLV, either: cnlNone(1) No LLDP Congestion Notification TLV is to carry Per-priority CNPV indicators or Per-priority Ready indicators on this Portfor this priority. cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector governs which LL…

Full description and source information

Identification

Identifier and names

Parent
1.0.8802.1.1.18.1.4.1 (ieee8021CnPortPriEntry)
Node code
7
Node name
ieee8021CnPortPriLldpInstanceChoice
Category
SNMP management object
Numeric OID
1.0.8802.1.1.18.1.4.1.7
URN notation
urn:oid:1.0.8802.1.1.18.1.4.1.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 0 8802 1 1 18 1 4 1 7}

  • {iso(1) standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnPortPriTable(4) ieee8021CnPortPriEntry(1) ieee8021CnPortPriLldpInstanceChoice(7)}
  • {iso(1) std(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnPortPriTable(4) ieee8021CnPortPriEntry(1) ieee8021CnPortPriLldpInstanceChoice(7)}
  • {iso(1) iso-standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnPortPriTable(4) ieee8021CnPortPriEntry(1) ieee8021CnPortPriLldpInstanceChoice(7)}
  • {iso(1) oidISO(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnPortPriTable(4) ieee8021CnPortPriEntry(1) ieee8021CnPortPriLldpInstanceChoice(7)}
OID-IRI notation
  • /1/0/8802/1/1/18/1/4/1/7
  • /ISO/Standard/8802/1/1/18/1/4/1/7
  • /ISO/0/8802/1/1/18/1/4/1/7
Named path variants
  • /iso/standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnPortPriTable/ieee8021CnPortPriEntry/ieee8021CnPortPriLldpInstanceChoice
  • /iso/std/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnPortPriTable/ieee8021CnPortPriEntry/ieee8021CnPortPriLldpInstanceChoice
  • /iso/iso-standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnPortPriTable/ieee8021CnPortPriEntry/ieee8021CnPortPriLldpInstanceChoice
  • /iso/oidISO/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnPortPriTable/ieee8021CnPortPriEntry/ieee8021CnPortPriLldpInstanceChoice

SNMP properties

Value type
Ieee8021CnLldpChoice
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
cnlComponent

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ieee8021CnPortPriLldpInstanceChoice OBJECT-TYPE 
         SYNTAX Ieee8021CnLldpChoice 
         MAX-ACCESS read-write 
         STATUS current 
         DESCRIPTION 
         "Specifies how to determine the LLDP instance to be used for the 
         Congestion Notification TLV, either:
         cnlNone(1) No LLDP Congestion Notification TLV is to 
         carry Per-priority CNPV indicators or 
         Per-priority Ready indicators on this Portfor this priority.
         cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector 
         governs which LLDP instance is to carry 
         Per-priority CNPV indicators and 
         Per-priority Ready indicators for this 
         priority in its Congestion Notification TLVon this Port

         cnlComponent(3) ieee8021CnComPriLldpInstanceChoice 
         governs LLDP instance selection for thisPort and priority.

         This object can override ieee8021CnComPriLldpInstanceChoice.
         " 
         REFERENCE 

         "802.1Qau clause 32.1.3, 32.4.4" 
         DEFVAL { cnlComponent } 
         ::= { ieee8021CnPortPriEntry 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Specifies how to determine the LLDP instance to be used for the Congestion Notification TLV, either: cnlNone(1) No LLDP Congestion Notification TLV is to carry Per-priority CNPV indicators or Per-priority Ready indicators on this Portfor this priority. cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector governs which LLDP instance is to carry Per-priority CNPV indicators and Per-priority Ready indicators for this priority in its Congestion Notification TLVon this Port cnlComponent(3) ieee8021CnComPriLldpInstanceChoice governs LLDP instance selection for thisPort and priority. This object can override ieee8021CnComPriLldpInstanceChoice.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 1

ieee8021CnPortPriLldpInstanceChoice · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: ieee8021CnPortPriLldpInstanceChoice

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021CnPortPriLldpInstanceChoice",
    "OBJECT-TYPE",
    "SYNTAX",
    "Ieee8021CnLldpChoice",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Specifies how to determine the LLDP instance to be used for the Congestion Notification TLV, either: cnlNone(1) No LLDP Congestion Notification TLV is to carry Per-priority CNPV indicators or Per-priority Ready indicators on this Portfor this priority. cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector governs which LLDP instance is to carry Per-priority CNPV indicators and Per-priority Ready indicators for this priority in its Congestion Notification TLVon this Port cnlComponent(3) ieee8021CnComPriLldpInstanceChoice governs LLDP instance selection for thisPort and priority. This object can override ieee8021CnComPriLldpInstanceChoice. \"",
    "REFERENCE",
    "\"802.1Qau clause 32.1.3, 32.4.4\"",
    "DEFVAL",
    "{",
    "cnlComponent",
    "}",
    "::=",
    "{",
    "ieee8021CnPortPriEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Ieee8021CnLldpChoice"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Specifies how to determine the LLDP instance to be used for the Congestion Notification TLV, either: cnlNone(1) No LLDP Congestion Notification TLV is to carry Per-priority CNPV indicators or Per-priority Ready indicators on this Portfor this priority. cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector governs which LLDP instance is to carry Per-priority CNPV indicators and Per-priority Ready indicators for this priority in its Congestion Notification TLVon this Port cnlComponent(3) ieee8021CnComPriLldpInstanceChoice governs LLDP instance selection for thisPort and priority. This object can override ieee8021CnComPriLldpInstanceChoice."
    ],
    [
      "REFERENCE",
      "802.1Qau clause 32.1.3, 32.4.4"
    ],
    null,
    null,
    [
      "DEFVAL",
      "cnlComponent"
    ]
  ]
}

Registration

Registration authorities

Current Registration Authority (inferred from ancestor 1.0)

ISO and IEC

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.0.8802.1.1.18.1.4.1.1 ieee8021CnPortPriComponentId00
1.0.8802.1.1.18.1.4.1.2 ieee8021CnPortPriority00
1.0.8802.1.1.18.1.4.1.3 ieee8021CnPortPriIfIndex00
1.0.8802.1.1.18.1.4.1.4 ieee8021CnPortPriDefModeChoice00
1.0.8802.1.1.18.1.4.1.5 ieee8021CnPortPriAdminDefenseMode00
1.0.8802.1.1.18.1.4.1.6 ieee8021CnPortPriAutoDefenseMode00
1.0.8802.1.1.18.1.4.1.8 ieee8021CnPortPriLldpInstanceSelector00
1.0.8802.1.1.18.1.4.1.9 ieee8021CnPortPriAlternatePriority00