OID reference

ieee8021CnCpFeedbackWeight

1.0.8802.1.1.18.1.5.1.8

Description

This object controls the weight (cpW) change in queue length in the calculation of cpFb when the Congestion Point is generating a Congestion Notification Message. The weight cpW is equal to two to the power of this object. Thus, if this object contains a -1, cpW = 1/2.

Full description and source information

Identification

Identifier and names

Parent
1.0.8802.1.1.18.1.5.1 (ieee8021CnCpEntry)
Node code
8
Node name
ieee8021CnCpFeedbackWeight
Category
SNMP management object
Numeric OID
1.0.8802.1.1.18.1.5.1.8
URN notation
urn:oid:1.0.8802.1.1.18.1.5.1.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 0 8802 1 1 18 1 5 1 8}

  • {iso(1) standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCpTable(5) ieee8021CnCpEntry(1) ieee8021CnCpFeedbackWeight(8)}
  • {iso(1) std(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCpTable(5) ieee8021CnCpEntry(1) ieee8021CnCpFeedbackWeight(8)}
  • {iso(1) iso-standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCpTable(5) ieee8021CnCpEntry(1) ieee8021CnCpFeedbackWeight(8)}
  • {iso(1) oidISO(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnCpTable(5) ieee8021CnCpEntry(1) ieee8021CnCpFeedbackWeight(8)}
OID-IRI notation
  • /1/0/8802/1/1/18/1/5/1/8
  • /ISO/Standard/8802/1/1/18/1/5/1/8
  • /ISO/0/8802/1/1/18/1/5/1/8
Named path variants
  • /iso/standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCpTable/ieee8021CnCpEntry/ieee8021CnCpFeedbackWeight
  • /iso/std/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCpTable/ieee8021CnCpEntry/ieee8021CnCpFeedbackWeight
  • /iso/iso-standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCpTable/ieee8021CnCpEntry/ieee8021CnCpFeedbackWeight
  • /iso/oidISO/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnCpTable/ieee8021CnCpEntry/ieee8021CnCpFeedbackWeight

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
-10–10

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: ieee8021CnCpComponentId, ieee8021CnCpIfIndex, ieee8021CnCpIndex.

snmpwalk [connection options] DEVICE .1.0.8802.1.1.18.1.5.1.8

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ieee8021CnCpFeedbackWeight OBJECT-TYPE 
         SYNTAX Integer32 (-10..10) 
         MAX-ACCESS read-write 
         STATUS current 
         DESCRIPTION 

         "This object controls the weight (cpW) change in queue length 
          in the calculation of cpFb when the Congestion Point is 
          generating a Congestion Notification Message.

          The weight cpW is equal to two to the power of this object. 
          Thus, if this object contains a -1, cpW = 1/2. " 
         REFERENCE 

          "802.1Qau clause 32.8.6" 
         DEFVAL { 1 } 
         ::= { ieee8021CnCpEntry 8 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This object controls the weight (cpW) change in queue length in the calculation of cpFb when the Congestion Point is generating a Congestion Notification Message. The weight cpW is equal to two to the power of this object. Thus, if this object contains a -1, cpW = 1/2.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 1

ieee8021CnCpFeedbackWeight · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: ieee8021CnCpFeedbackWeight

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021CnCpFeedbackWeight",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "10",
    ".",
    ".",
    "10",
    ")",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object controls the weight (cpW) change in queue length in the calculation of cpFb when the Congestion Point is generating a Congestion Notification Message. The weight cpW is equal to two to the power of this object. Thus, if this object contains a -1, cpW = 1/2. \"",
    "REFERENCE",
    "\"802.1Qau clause 32.8.6\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "ieee8021CnCpEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -10,
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object controls the weight (cpW) change in queue length in the calculation of cpFb when the Congestion Point is generating a Congestion Notification Message. The weight cpW is equal to two to the power of this object. Thus, if this object contains a -1, cpW = 1/2."
    ],
    [
      "REFERENCE",
      "802.1Qau clause 32.8.6"
    ],
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}

Registration

Registration authorities

Current Registration Authority (inferred from ancestor 1.0)

ISO and IEC

Siblings (12)

OIDNameDirect childrenDescendantsDescription
1.0.8802.1.1.18.1.5.1.1 ieee8021CnCpComponentId00
1.0.8802.1.1.18.1.5.1.2 ieee8021CnCpIfIndex00
1.0.8802.1.1.18.1.5.1.3 ieee8021CnCpIndex00
1.0.8802.1.1.18.1.5.1.4 ieee8021CnCpPriority00
1.0.8802.1.1.18.1.5.1.5 ieee8021CnCpMacAddress00
1.0.8802.1.1.18.1.5.1.6 ieee8021CnCpIdentifier00
1.0.8802.1.1.18.1.5.1.7 ieee8021CnCpQueueSizeSetPoint00
1.0.8802.1.1.18.1.5.1.9 ieee8021CnCpMinSampleBase00
1.0.8802.1.1.18.1.5.1.10 ieee8021CnCpDiscardedFrames00
1.0.8802.1.1.18.1.5.1.11 ieee8021CnCpTransmittedFrames00
1.0.8802.1.1.18.1.5.1.12 ieee8021CnCpTransmittedCnms00
1.0.8802.1.1.18.1.5.1.13 ieee8021CnCpMinHeaderOctets00