OID reference

ieee8021CnRpPortPriCentiseconds

1.0.8802.1.1.18.1.7.1.6

Description

This object returns the total number of centi-seconds that any of the Reaction Points (RPs) controlled by this entry has had its rpEnabled variable in the TRUE state. That is, once each centi-second, this counter is incremented by the number of RPs this entry controls that are actively rate limiting output frames. Div…

Full description and source information

Identification

Identifier and names

Parent
1.0.8802.1.1.18.1.7.1 (ieee8021CnRpPortPriEntry)
Node code
6
Node name
ieee8021CnRpPortPriCentiseconds
Category
SNMP management object
Numeric OID
1.0.8802.1.1.18.1.7.1.6
URN notation
urn:oid:1.0.8802.1.1.18.1.7.1.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 0 8802 1 1 18 1 7 1 6}

  • {iso(1) standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpPortPriTable(7) ieee8021CnRpPortPriEntry(1) ieee8021CnRpPortPriCentiseconds(6)}
  • {iso(1) std(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpPortPriTable(7) ieee8021CnRpPortPriEntry(1) ieee8021CnRpPortPriCentiseconds(6)}
  • {iso(1) iso-standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpPortPriTable(7) ieee8021CnRpPortPriEntry(1) ieee8021CnRpPortPriCentiseconds(6)}
  • {iso(1) oidISO(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpPortPriTable(7) ieee8021CnRpPortPriEntry(1) ieee8021CnRpPortPriCentiseconds(6)}
OID-IRI notation
  • /1/0/8802/1/1/18/1/7/1/6
  • /ISO/Standard/8802/1/1/18/1/7/1/6
  • /ISO/0/8802/1/1/18/1/7/1/6
Named path variants
  • /iso/standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpPortPriTable/ieee8021CnRpPortPriEntry/ieee8021CnRpPortPriCentiseconds
  • /iso/std/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpPortPriTable/ieee8021CnRpPortPriEntry/ieee8021CnRpPortPriCentiseconds
  • /iso/iso-standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpPortPriTable/ieee8021CnRpPortPriEntry/ieee8021CnRpPortPriCentiseconds
  • /iso/oidISO/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpPortPriTable/ieee8021CnRpPortPriEntry/ieee8021CnRpPortPriCentiseconds

SNMP properties

Value type
Counter64
Units
centiseconds
Maximum access defined by MIB
read-only
Status in MIB
current

Interpreting this counter

A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.

Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.

Published counter width: 64 bits. SMIv2: Counter32 · Counter64

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: ieee8021CnRpPortPriComponentId, ieee8021CnRpPortPriPriority, ieee8021CnRpPortPriIfIndex.

snmpwalk [connection options] DEVICE .1.0.8802.1.1.18.1.7.1.6

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ieee8021CnRpPortPriCentiseconds OBJECT-TYPE

        SYNTAX Counter64 
        UNITS "centiseconds" 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION 

        "This object returns the total number of centi-seconds that 
        any of the Reaction Points (RPs) controlled by this entry 
        has had its rpEnabled variable in the TRUE state. That is, 
        once each centi-second, this counter is incremented by the 
        number of RPs this entry controls that are actively rate 
        limiting output frames.

        Dividing the change in this object over a time interval by the 
        length of the interval yields the average number of RPs active 
        over that interval. Dividing the change in this object by the 
        change in ieee8021CnRpPortPriCreatedRps over that same time 
        interval yields the average lifetime of an active RP during thatinterval. 

        " 
        REFERENCE 
        "802.1Qau clause 32.10.3, 32.13.1" 
        ::= { ieee8021CnRpPortPriEntry 6 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This object returns the total number of centi-seconds that any of the Reaction Points (RPs) controlled by this entry has had its rpEnabled variable in the TRUE state. That is, once each centi-second, this counter is incremented by the number of RPs this entry controls that are actively rate limiting output frames. Dividing the change in this object over a time interval by the length of the interval yields the average number of RPs active over that interval. Dividing the change in this object by the change in ieee8021CnRpPortPriCreatedRps over that same time interval yields the average lifetime of an active RP during thatinterval.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 1

ieee8021CnRpPortPriCentiseconds · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: ieee8021CnRpPortPriCentiseconds

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021CnRpPortPriCentiseconds",
    "OBJECT-TYPE",
    "SYNTAX",
    "Counter64",
    "UNITS",
    [
      "literal",
      "2263656e74697365636f6e647322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object returns the total number of centi-seconds that any of the Reaction Points (RPs) controlled by this entry has had its rpEnabled variable in the TRUE state. That is, once each centi-second, this counter is incremented by the number of RPs this entry controls that are actively rate limiting output frames. Dividing the change in this object over a time interval by the length of the interval yields the average number of RPs active over that interval. Dividing the change in this object by the change in ieee8021CnRpPortPriCreatedRps over that same time interval yields the average lifetime of an active RP during thatinterval. \"",
    "REFERENCE",
    "\"802.1Qau clause 32.10.3, 32.13.1\"",
    "::=",
    "{",
    "ieee8021CnRpPortPriEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Counter64"
    ],
    [
      "UNITS",
      "centiseconds"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object returns the total number of centi-seconds that any of the Reaction Points (RPs) controlled by this entry has had its rpEnabled variable in the TRUE state. That is, once each centi-second, this counter is incremented by the number of RPs this entry controls that are actively rate limiting output frames. Dividing the change in this object over a time interval by the length of the interval yields the average number of RPs active over that interval. Dividing the change in this object by the change in ieee8021CnRpPortPriCreatedRps over that same time interval yields the average lifetime of an active RP during thatinterval."
    ],
    [
      "REFERENCE",
      "802.1Qau clause 32.10.3, 32.13.1"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

Current Registration Authority (inferred from ancestor 1.0)

ISO and IEC

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.0.8802.1.1.18.1.7.1.1 ieee8021CnRpPortPriComponentId00
1.0.8802.1.1.18.1.7.1.2 ieee8021CnRpPortPriPriority00
1.0.8802.1.1.18.1.7.1.3 ieee8021CnRpPortPriIfIndex00
1.0.8802.1.1.18.1.7.1.4 ieee8021CnRpPortPriMaxRps00
1.0.8802.1.1.18.1.7.1.5 ieee8021CnRpPortPriCreatedRps00