OID reference

ieee8021CnRpGroupTable

1.0.8802.1.1.18.1.8

Description

Each row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can ha…

Full description and source information

Identification

Identifier and names

Parent
1.0.8802.1.1.18.1 (ieee8021CnMIBObjects)
Node code
8
Node name
ieee8021CnRpGroupTable
Category
SNMP management object
Numeric OID
1.0.8802.1.1.18.1.8
URN notation
urn:oid:1.0.8802.1.1.18.1.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 0 8802 1 1 18 1 8}

  • {iso(1) standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpGroupTable(8)}
  • {iso(1) std(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpGroupTable(8)}
  • {iso(1) iso-standard(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpGroupTable(8)}
  • {iso(1) oidISO(0) iso8802(8802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021CnMib(18) ieee8021CnMIBObjects(1) ieee8021CnRpGroupTable(8)}
OID-IRI notation
  • /1/0/8802/1/1/18/1/8
  • /ISO/Standard/8802/1/1/18/1/8
  • /ISO/0/8802/1/1/18/1/8
Named path variants
  • /iso/standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpGroupTable
  • /iso/std/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpGroupTable
  • /iso/iso-standard/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpGroupTable
  • /iso/oidISO/iso8802/ieee802dot1/ieee802dot1mibs/ieee8021CnMib/ieee8021CnMIBObjects/ieee8021CnRpGroupTable

SNMP properties

Value type
SEQUENCE OF Ieee8021CnRpGroupEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ieee8021CnRpGroupTable OBJECT-TYPE 
        SYNTAX SEQUENCE OF Ieee8021CnRpGroupEntry 
        MAX-ACCESS not-accessible 
        STATUS current 
        DESCRIPTION 

        "Each row in this table supplies values for one or more 
        Reaction Points (RPs). This table is indexed by component, 
        port (interface), and an arbitrary RP index.

        Creating an entry in ieee8021CnCompntPriTable can create an 
        entry in this table, with the default values, on all ports 
        in the end station. An end station can have more than one 
        RP for the same Congestion Notification Priority Value 
        (CNPV), so creating an entry in ieee8021CnCompntPriTable can 
        create multiple entries in this table.

        Because each port in a bridge component or end station can have 
        a different relationship between CNPVs and RPs, the entries 
        created or deleted on each port can be different.

        Deleting the an entry in ieee8021CnCompntPriTable for a 
        CNPV passing through the RP controlled by this entry deletes 
        entries on some or all of the ports in the end station.

        Because each port in an end station can have a 
        different relationship between CNPVs and RPs, the entries 
        created or deleted on each port can be different.

        The relationship between ieee8021CnRpgIdentifier

        values and RPs is an implementation dependent matter.

        The contents of this table SHALL be maintained across a restart 
        of the system, except as noted in the description of 
        ieee8021CnRpgIfIndex.

        "

        REFERENCE
        "802.1Qau clause 12.17.6"


        ::= { ieee8021CnMIBObjects 8 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Each row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can have more than one RP for the same Congestion Notification Priority Value (CNPV), so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. Deleting the an entry in ieee8021CnCompntPriTable for a CNPV passing through the RP controlled by this entry deletes entries on some or all of the ports in the end station. Because each port in an end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnRpgIdentifier values and RPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnRpgIfIndex.

Sources for this description

Belden, GarrettCom and Hirschmann IT official standalone MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Belden, GarrettCom and Hirschmann IT official standalone MIBs1 record · 1 source

Description 1

ieee8021CnRpGroupTable · currentBelden, GarrettCom and Hirschmann IT official standalone MIBs1 source

Status in source: current.

Names: ieee8021CnRpGroupTable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021CnRpGroupTable",
    "OBJECT-TYPE",
    "SYNTAX",
    "SEQUENCE",
    "OF",
    "Ieee8021CnRpGroupEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Each row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can have more than one RP for the same Congestion Notification Priority Value (CNPV), so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. Deleting the an entry in ieee8021CnCompntPriTable for a CNPV passing through the RP controlled by this entry deletes entries on some or all of the ports in the end station. Because each port in an end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnRpgIdentifier values and RPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnRpgIfIndex. \"",
    "REFERENCE",
    "\"802.1Qau clause 12.17.6\"",
    "::=",
    "{",
    "ieee8021CnMIBObjects",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "conceptualTable",
      [
        "row",
        "Ieee8021CnRpGroupEntry"
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Each row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can have more than one RP for the same Congestion Notification Priority Value (CNPV), so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. Deleting the an entry in ieee8021CnCompntPriTable for a CNPV passing through the RP controlled by this entry deletes entries on some or all of the ports in the end station. Because each port in an end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnRpgIdentifier values and RPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnRpgIfIndex."
    ],
    [
      "REFERENCE",
      "802.1Qau clause 12.17.6"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

Current Registration Authority (inferred from ancestor 1.0)

ISO and IEC

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.0.8802.1.1.18.1.8.1 ieee8021CnRpGroupEntry1414

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.0.8802.1.1.18.1.1 ieee8021CnGlobalTable15
1.0.8802.1.1.18.1.2 ieee8021CnErroredPortTable14
1.0.8802.1.1.18.1.3 ieee8021CnCompntPriTable111
1.0.8802.1.1.18.1.4 ieee8021CnPortPriTable110
1.0.8802.1.1.18.1.5 ieee8021CnCpTable114
1.0.8802.1.1.18.1.6 ieee8021CnCpidToInterfaceTable15
1.0.8802.1.1.18.1.7 ieee8021CnRpPortPriTable17