Reference record for OID 1.2.840.10036.4.5.1.3


parent
1.2.840.10036.4.5.1 (dot11PhyDSSSEntry)
node code
3
node name
dot11CurrentCCAMode
dot oid
1.2.840.10036.4.5.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11phy(4) dot11PhyDSSSTable(5) dot11PhyDSSSEntry(1) dot11CurrentCCAMode(3)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11phy/dot11PhyDSSSTable/dot11PhyDSSSEntry/dot11CurrentCCAMode
  • iri by oid_info
    /ISO/Member-Body/US/10036/4/5/1/3

    Description by circitor

    The current CCA method in operation. Valid values are:
    energy detect only (edonly) = 01,
    carrier sense only (csonly) = 02,
    carrier sense and energy detect (edandcs)= 04
    carrier sense with timer (cswithtimer)= 08
    high rate carrier sense and energy detect (hrcsanded)=16.

    Parsed from file IEEE802dot11-MIB.mib
    Module: IEEE802dot11-MIB

    Description by cisco_v1

    The current CCA method in operation. Valid values are:
    energy detect only (edonly) = 01,
    carrier sense only (csonly) = 02,
    carrier sense and energy detect (edandcs)= 04
    carrier sense with timer (cswithtimer)= 08
    high rate carrier sense and energy detect (hrcsanded)=16.

    Description by oid_info

    dot11CurrentCCAMode OBJECT-TYPE
    SYNTAX INTEGER {edonly(1), csonly(2), edandcs(4)}
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The current CCA method in operation. Valid values are:
    energy detect only (edonly) = 01,
    carrier sense only (csonly) = 02,
    carrier sense and energy detect (edandcs)= 04."

    View at oid-info.com

    Description by mibdepot

    This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the implementation.

    The current CCA method in operation. Valid values are:
    energy detect only (edonly) = 01,
    carrier sense only (csonly) = 02,
    carrier sense and energy detect (edandcs)= 04
    carrier sense with timer (cswithtimer)= 08
    high rate carrier sense and energy detect (hrcsanded)=16.

    Parsed from file 802_11mib.txt
    Company: None
    Module: IEEE802dot11-MIB

    Description by cisco

    The current CCA method in operation. Valid values are:
    energy detect only (edonly) = 01,
    carrier sense only (csonly) = 02,
    carrier sense and energy detect (edandcs)= 04
    carrier sense with timer (cswithtimer)= 08
    high rate carrier sense and energy detect (hrcsanded)=16.

    Information by circitor

    dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), edandcs(4), cswithtimer(8), hrcsanded(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16." ::= { dot11PhyDSSSEntry 3 }

    Information by cisco_v1

    dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), edandcs(4), cswithtimer(8), hrcsanded(16) } ACCESS read-write STATUS mandatory DESCRIPTION "The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16." ::= { dot11PhyDSSSEntry 3 }

    Information by oid_info

    Automatically extracted from Cisco "SNMP v2 MIBs".

    Information by mibdepot

    dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), edandcs(4), cswithtimer(8), hrcsanded(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16." ::= { dot11PhyDSSSEntry 3 }

    Information by cisco

    dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), edandcs(4), cswithtimer(8), hrcsanded(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16." ::= { dot11PhyDSSSEntry 3 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.4.5.1.1 dot11CurrentChannel 0 0 The current operating frequency channel of the DSSS
    PHY. Valid channel numbers are as defined in 15.4.6.2
    1.2.840.10036.4.5.1.2 dot11CCAModeSupported 0 0 dot11CCAModeSupported OBJECT-TYPE
    SYNTAX INTEGER (1..7)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "dot11CCAModeSupported …
    1.2.840.10036.4.5.1.4 dot11EDThreshold 0 0 The current Energy Detect Threshold being used by the DSSS PHY.