Reference record for OID 1.2.840.10036.6.3.1.5


parent
1.2.840.10036.6.3.1 (dot11APLCIEntry)
node code
5
node name
dot11APLCILongitudeResolution
dot oid
1.2.840.10036.6.3.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11imt(6) dot11APLCITable(3) dot11APLCIEntry(1) dot11APLCILongitudeResolution(5)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11imt/dot11APLCITable/dot11APLCIEntry/dot11APLCILongitudeResolution
  • iri by oid_info
    /ISO/Member-Body/US/10036/6/3/1/5

    Description by mibdepot

    This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical in the implementation.

    Longitude resolution is 6 bits indicating the number of valid bits in the fixed-point value of Longitude. This field is derived from IETF RFC 3825.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-write
    Syntax: Unsigned32
    (
    0..63 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11APLCILongitudeResolution OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude resolution is 6 bits indicating the number of valid bits in the fixed-point value of Longitude. This field is derived from IETF RFC 3825." ::= { dot11APLCIEntry 5 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.6.3.1.1 dot11APLCIIndex 0 0 Index for AP LCI elements in dot11APLCITable, greater than 0.
    1.2.840.10036.6.3.1.2 dot11APLCILatitudeResolution 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.3 dot11APLCILatitudeInteger 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.4 dot11APLCILatitudeFraction 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.6 dot11APLCILongitudeInteger 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.7 dot11APLCILongitudeFraction 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.8 dot11APLCIAltitudeType 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.9 dot11APLCIAltitudeResolution 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.10 dot11APLCIAltitudeInteger 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.11 dot11APLCIAltitudeFraction 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.12 dot11APLCIDatum 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.13 dot11APLCIAzimuthType 0 0 dot11APLCIAzimuthtype
    1.2.840.10036.6.3.1.14 dot11APLCIAzimuthResolution 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …
    1.2.840.10036.6.3.1.15 dot11APLCIAzimuth 0 0 This is a control variable.

    It is written by an external management entity or the SME.
    Changes take effect as soon as practical …