The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status in source: current.
Names: ieee8021PSFPStreamBlockedDueToOversizeFrameEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021PSFPStreamBlockedDueToOversizeFrameEnable",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.\"",
"REFERENCE",
"\"8.6.5.1, 8.6.5.1.1, 12.31.2\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"ieee8021PSFPStreamFilterEntry",
"12",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system."
],
[
"REFERENCE",
"8.6.5.1, 8.6.5.1.1, 12.31.2"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamBlockedDueToOversizeFrameEnable.Source version and references
Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256:
c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamBlockedDueToOversizeFrameEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object \r\n contains a Boolean value that indicates whether the \r\n ieee8021PSFPStreamBlockedDueToOversizeFrame function is\r\n enabled (TRUE) or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.1, 12.31.2"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPStreamFilterEntry 12 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.1, 12.31.2'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamBlockedDueToOversizeFrameEnable.Source version and references
Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256:
d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamBlockedDueToOversizeFrameEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object \r\n contains a Boolean value that indicates whether the \r\n ieee8021PSFPStreamBlockedDueToOversizeFrame function is\r\n enabled (TRUE) or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.1, 12.31.2"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPStreamFilterEntry 12 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the ieee8021PSFPStreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.1, 12.31.2'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}