Reference record for OID 1.3.111.2.802.1.1.31.1.1.1.1.5

Parent
1.3.111.2.802.1.1.31.1.1.1.1 (ieee8021PSFPStreamFilterEntry)
Node code
5
Node name
ieee8021PSFPFilterSpecificationList
Numeric OID
1.3.111.2.802.1.1.31.1.1.1.1.5
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.1.1.1.5
ASN.1 notation

{1 3 111 2 802 1 1 31 1 1 1 1 5}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamFilterParameters(1) ieee8021PSFPStreamFilterTable(1) ieee8021PSFPStreamFilterEntry(1) ieee8021PSFPFilterSpecificationList(5)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/1/1/1/5
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/1/1/1/5
  • /ISO/3/111/2/802/1/1/31/1/1/1/1/5
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamFilterParameters/ieee8021PSFPStreamFilterTable/ieee8021PSFPStreamFilterEntry/ieee8021PSFPFilterSpecificationList

Source records

The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFilterSpecificationList

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFilterSpecificationList",
    "OBJECT-TYPE",
    "SYNTAX",
    "OCTET",
    "STRING",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.1, 12.31.2\"",
    "::=",
    "{",
    "ieee8021PSFPStreamFilterEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OCTET STRING"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.1, 12.31.2"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFilterSpecificationList.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFilterSpecificationList OBJECT-TYPE\r\n    SYNTAX      OCTET STRING \r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FilterSpecificationList parameter contains a list of  \r\n        filter specifications associated with this stream filter.\r\n\r\n        The octet string value represents the contents of the list as\r\n        an ordered list of entries, each encoded as a TLV, as follows.\r\n\r\n        The first octet  of each TLV is interpreted as an\r\n        unsigned integer representing a filter specification type:\r\n            0: Maximum SDU Size.\r\n            1: Flow meter instance identifier.\r\n            2-255: Reserved for future gate operations\r\n            \r\n        The second and third octets of the TLV are the length field, \r\n        interpreted as an unsigned integer, indicating the number of\r\n        octets of the value that follows the length. A length of\r\n        zero indicates that there is no value \r\n        (i.e., the filter specification has no parameters).\r\n        \r\n        The fourth through (4 + length -1)th octets encode the \r\n        parameters of the filter specification, as defined for each\r\n        filter specification type.\r\n        \r\n        - Maximum SDU Size:\r\n            A single SDU size parameter is encoded in four octets, and\r\n            is interpreted as an unsigned integer value.\r\n            \r\n        - Flow meter instance identifier:\r\n            A single flow meter instance identifier is encoded in\r\n            four octets, and is interpreted as an unsigned integer value.\r\n             \r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.2"\r\n    ::= { ieee8021PSFPStreamFilterEntry 5}', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFilterSpecificationList.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFilterSpecificationList OBJECT-TYPE\r\n    SYNTAX      OCTET STRING \r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FilterSpecificationList parameter contains a list of  \r\n        filter specifications associated with this stream filter.\r\n\r\n        The octet string value represents the contents of the list as\r\n        an ordered list of entries, each encoded as a TLV, as follows.\r\n\r\n        The first octet  of each TLV is interpreted as an\r\n        unsigned integer representing a filter specification type:\r\n            0: Maximum SDU Size.\r\n            1: Flow meter instance identifier.\r\n            2-255: Reserved for future gate operations\r\n            \r\n        The second and third octets of the TLV are the length field, \r\n        interpreted as an unsigned integer, indicating the number of\r\n        octets of the value that follows the length. A length of\r\n        zero indicates that there is no value \r\n        (i.e., the filter specification has no parameters).\r\n        \r\n        The fourth through (4 + length -1)th octets encode the \r\n        parameters of the filter specification, as defined for each\r\n        filter specification type.\r\n        \r\n        - Maximum SDU Size:\r\n            A single SDU size parameter is encoded in four octets, and\r\n            is interpreted as an unsigned integer value.\r\n            \r\n        - Flow meter instance identifier:\r\n            A single flow meter instance identifier is encoded in\r\n            four octets, and is interpreted as an unsigned integer value.\r\n             \r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.2"\r\n    ::= { ieee8021PSFPStreamFilterEntry 5}', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future gate operations The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFilterSpecificationList

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFilterSpecificationList",
    "OBJECT-TYPE",
    "SYNTAX",
    "OCTET",
    "STRING",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.2.1, 8.6.5.3, 12.31.2\"",
    "::=",
    "{",
    "ieee8021PSFPStreamFilterEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OCTET STRING"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.2.1, 8.6.5.3, 12.31.2"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFilterSpecificationList.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFilterSpecificationList OBJECT-TYPE\n    SYNTAX      OCTET STRING \n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FilterSpecificationList parameter contains a list of  \n        filter specifications associated with this stream filter.\n\n        The octet string value represents the contents of the list as\n        an ordered list of entries, each encoded as a TLV, as follows.\n\n        The first octet  of each TLV is interpreted as an\n        unsigned integer representing a filter specification type:\n            0: Maximum SDU Size.\n            1: Flow meter instance identifier.\n            2-255: Reserved for future filter specification types\n            \n        The second and third octets of the TLV are the length field, \n        interpreted as an unsigned integer, indicating the number of\n        octets of the value that follows the length. A length of\n        zero indicates that there is no value \n        (i.e., the filter specification has no parameters).\n        \n        The fourth through (4 + length -1)th octets encode the \n        parameters of the filter specification, as defined for each\n        filter specification type.\n        \n        - Maximum SDU Size:\n            A single SDU size parameter is encoded in four octets, and\n            is interpreted as an unsigned integer value.\n            \n        - Flow meter instance identifier:\n            A single flow meter instance identifier is encoded in\n            four octets, and is interpreted as an unsigned integer value.\n             \n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.2.1, 8.6.5.3, 12.31.2"\n    ::= { ieee8021PSFPStreamFilterEntry 5}', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.2.1, 8.6.5.3, 12.31.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFilterSpecificationList.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFilterSpecificationList OBJECT-TYPE\n    SYNTAX      OCTET STRING \n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FilterSpecificationList parameter contains a list of  \n        filter specifications associated with this stream filter.\n\n        The octet string value represents the contents of the list as\n        an ordered list of entries, each encoded as a TLV, as follows.\n\n        The first octet  of each TLV is interpreted as an\n        unsigned integer representing a filter specification type:\n            0: Maximum SDU Size.\n            1: Flow meter instance identifier.\n            2-255: Reserved for future filter specification types\n            \n        The second and third octets of the TLV are the length field, \n        interpreted as an unsigned integer, indicating the number of\n        octets of the value that follows the length. A length of\n        zero indicates that there is no value \n        (i.e., the filter specification has no parameters).\n        \n        The fourth through (4 + length -1)th octets encode the \n        parameters of the filter specification, as defined for each\n        filter specification type.\n        \n        - Maximum SDU Size:\n            A single SDU size parameter is encoded in four octets, and\n            is interpreted as an unsigned integer value.\n            \n        - Flow meter instance identifier:\n            A single flow meter instance identifier is encoded in\n            four octets, and is interpreted as an unsigned integer value.\n             \n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.2.1, 8.6.5.3, 12.31.2"\n    ::= { ieee8021PSFPStreamFilterEntry 5}', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.2.1, 8.6.5.3, 12.31.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFilterSpecificationList.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFilterSpecificationList OBJECT-TYPE\r\n    SYNTAX      OCTET STRING \r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FilterSpecificationList parameter contains a list of  \r\n        filter specifications associated with this stream filter.\r\n\r\n        The octet string value represents the contents of the list as\r\n        an ordered list of entries, each encoded as a TLV, as follows.\r\n\r\n        The first octet  of each TLV is interpreted as an\r\n        unsigned integer representing a filter specification type:\r\n            0: Maximum SDU Size.\r\n            1: Flow meter instance identifier.\r\n            2-255: Reserved for future filter specification types\r\n            \r\n        The second and third octets of the TLV are the length field, \r\n        interpreted as an unsigned integer, indicating the number of\r\n        octets of the value that follows the length. A length of\r\n        zero indicates that there is no value \r\n        (i.e., the filter specification has no parameters).\r\n        \r\n        The fourth through (4 + length -1)th octets encode the \r\n        parameters of the filter specification, as defined for each\r\n        filter specification type.\r\n        \r\n        - Maximum SDU Size:\r\n            A single SDU size parameter is encoded in four octets, and\r\n            is interpreted as an unsigned integer value.\r\n            \r\n        - Flow meter instance identifier:\r\n            A single flow meter instance identifier is encoded in\r\n            four octets, and is interpreted as an unsigned integer value.\r\n             \r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.2.1, 8.6.5.3, 12.31.2"\r\n    ::= { ieee8021PSFPStreamFilterEntry 5}', 'syntax_tree': [['SimpleSyntax', 'OCTET STRING'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.2.1, 8.6.5.3, 12.31.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (13)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.1.1.1.1 ieee8021PSFPStreamFilterInstance00
1.3.111.2.802.1.1.31.1.1.1.1.2 ieee8021PSFPStreamHandleSpec00
1.3.111.2.802.1.1.31.1.1.1.1.3 ieee8021PSFPPrioritySpec00
1.3.111.2.802.1.1.31.1.1.1.1.4 ieee8021PSFPStreamGateInstanceID00
1.3.111.2.802.1.1.31.1.1.1.1.6 ieee8021PSFPMatchingFramesCount00
1.3.111.2.802.1.1.31.1.1.1.1.7 ieee8021PSFPPassingFramesCount00
1.3.111.2.802.1.1.31.1.1.1.1.8 ieee8021PSFPNotPassingFramesCount00
1.3.111.2.802.1.1.31.1.1.1.1.9 ieee8021PSFPPassingSDUCount00
1.3.111.2.802.1.1.31.1.1.1.1.10 ieee8021PSFPNotPassingSDUCount00
1.3.111.2.802.1.1.31.1.1.1.1.11 ieee8021PSFPREDFramesCount00
1.3.111.2.802.1.1.31.1.1.1.1.12 ieee8021PSFPStreamBlockedDueToOversizeFrameEnable00
1.3.111.2.802.1.1.31.1.1.1.1.13 ieee8021PSFPStreamBlockedDueToOversizeFrame00
1.3.111.2.802.1.1.31.1.1.1.1.14 ieee8021PSFPStreamFilterEntryRowStatus00