This managed object indicates whether an instance of the Latent error detection function is to be instantiated along with the Base recovery function in this recovery function. It cannot be set True if ieee8021FrerSequenceRecoveryIndividualRecovery is also True; an Individual recovery function does not include a Latent error detection function.
Status in source: current.
Names: ieee8021FrerSequenceRecoveryLatentErrorDetection
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021FrerSequenceRecoveryLatentErrorDetection",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This managed object indicates whether an instance of the Latent error detection function is to be instantiated along with the Base recovery function in this recovery function. It cannot be set True if ieee8021FrerSequenceRecoveryIndividualRecovery is also True; an Individual recovery function does not include a Latent error detection function.\"",
"REFERENCE",
"\"10.4.1.11\"",
"::=",
"{",
"ieee8021FrerSequenceRecoveryEntry",
"15",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This managed object indicates whether an instance of the Latent error detection function is to be instantiated along with the Base recovery function in this recovery function. It cannot be set True if ieee8021FrerSequenceRecoveryIndividualRecovery is also True; an Individual recovery function does not include a Latent error detection function."
],
[
"REFERENCE",
"10.4.1.11"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-FRER-MIB::ieee8021FrerSequenceRecoveryLatentErrorDetection.Source version and references
Downloaded: 2026-10-19T00:21:33.985475+00:00. SHA-256:
49835dfa7b21b0f0c35727922c63900636f0a07fd00cced17f9ec356e42bf30f{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-FRER-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-STREAM-IDENTIFICATION-MIB': ['Ieee8021CBTaggedType', 'Ieee8021CBVlanIdentifier', 'Ieee8021CBLanPathIdType', 'ieee8021StreamIdStreamIdHandle']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021FrerSequenceRecoveryLatentErrorDetection OBJECT-TYPE\n SYNTAX TruthValue\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "This managed object indicates whether an instance of the\n Latent error detection function is to be instantiated along\n with the Base recovery function in this recovery function.\n It cannot be set True if\n ieee8021FrerSequenceRecoveryIndividualRecovery is also True;\n an Individual recovery function does not include a Latent\n error detection function."\n REFERENCE "10.4.1.11"\n ::= { ieee8021FrerSequenceRecoveryEntry 15 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'This managed object indicates whether an instance of the Latent error detection function is to be instantiated along with the Base recovery function in this recovery function. It cannot be set True if ieee8021FrerSequenceRecoveryIndividualRecovery is also True; an Individual recovery function does not include a Latent error detection function.'], ['REFERENCE', '10.4.1.11'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}