This managed object specifies the number of milliseconds that are to elapse between instances of running the LatentErrorTest function. An implementation can have a minimum value for this managed object, below which it cannot be set, but this minimum shall be no larger than 1000 ms (1 s). Default value 2000 (2 s). It is used if and only if ieee8021FrerSequenceRecoveryIndividualRecovery is False.
Status in source: current.
Names: ieee8021FrerSequenceRecoveryLatentErrorPeriod
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021FrerSequenceRecoveryLatentErrorPeriod",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This managed object specifies the number of milliseconds that are to elapse between instances of running the LatentErrorTest function. An implementation can have a minimum value for this managed object, below which it cannot be set, but this minimum shall be no larger than 1000 ms (1 s). Default value 2000 (2 s). It is used if and only if ieee8021FrerSequenceRecoveryIndividualRecovery is False.\"",
"REFERENCE",
"\"10.4.1.12.2\"",
"DEFVAL",
"{",
"2000",
"}",
"::=",
"{",
"ieee8021FrerSequenceRecoveryEntry",
"17",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This managed object specifies the number of milliseconds that are to elapse between instances of running the LatentErrorTest function. An implementation can have a minimum value for this managed object, below which it cannot be set, but this minimum shall be no larger than 1000 ms (1 s). Default value 2000 (2 s). It is used if and only if ieee8021FrerSequenceRecoveryIndividualRecovery is False."
],
[
"REFERENCE",
"10.4.1.12.2"
],
null,
null,
[
"DEFVAL",
2000
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-FRER-MIB::ieee8021FrerSequenceRecoveryLatentErrorPeriod.Source version and references
Downloaded: 2026-10-19T00:21:33.985475+00:00. SHA-256:
49835dfa7b21b0f0c35727922c63900636f0a07fd00cced17f9ec356e42bf30f{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-FRER-MIB', 'imports': {'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'AutonomousType', 'VariablePointer'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter64', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-STREAM-IDENTIFICATION-MIB': ['Ieee8021CBTaggedType', 'Ieee8021CBVlanIdentifier', 'Ieee8021CBLanPathIdType', 'ieee8021StreamIdStreamIdHandle']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021FrerSequenceRecoveryLatentErrorPeriod OBJECT-TYPE\n SYNTAX Integer32\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "This managed object specifies the number of milliseconds that\n are to elapse between instances of running the LatentErrorTest\n function. An implementation can have a minimum value for\n this managed object, below which it cannot be set, but this\n minimum shall be no larger than 1000 ms (1 s).\n Default value 2000 (2 s).\n It is used if and only if\n ieee8021FrerSequenceRecoveryIndividualRecovery is False."\n REFERENCE "10.4.1.12.2"\n DEFVAL { 2000 }\n ::= { ieee8021FrerSequenceRecoveryEntry 17 }', 'syntax_tree': [['SimpleSyntax', 'Integer32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'This managed object specifies the number of milliseconds that are to elapse between instances of running the LatentErrorTest function. An implementation can have a minimum value for this managed object, below which it cannot be set, but this minimum shall be no larger than 1000 ms (1 s). Default value 2000 (2 s). It is used if and only if ieee8021FrerSequenceRecoveryIndividualRecovery is False.'], ['REFERENCE', '10.4.1.12.2'], None, None, ['DEFVAL', 2000]], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}