The asymmetryMeasurementModeDS represents the capability to enable/disable the Asymmetry Compensation Measurement Procedure on a PTP Port (see Annex G). This data set is used instead of the cmldsAsymmetryMeasurementModeDS, when only domain 0 is present and CMLDS is not used.
Status in source: current.
Names: ieee8021AsV3AsymMeasurementModeDSEntry
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV3AsymMeasurementModeDSEntry",
"OBJECT-TYPE",
"SYNTAX",
"Ieee8021AsV3AsymMeasurementModeDSEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The asymmetryMeasurementModeDS represents the capability to enable/disable the Asymmetry Compensation Measurement Procedure on a PTP Port (see Annex G). This data set is used instead of the cmldsAsymmetryMeasurementModeDS, when only domain 0 is present and CMLDS is not used. \"",
"INDEX",
"{",
"ieee8021AsV3PtpInstance",
",",
"ieee8021AsV3AsymMeasurementModeDSAsIndex",
"}",
"::=",
"{",
"ieee8021AsV3AsymMeasurementModeDSTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"Ieee8021AsV3AsymMeasurementModeDSEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The asymmetryMeasurementModeDS represents the capability to enable/disable the Asymmetry Compensation Measurement Procedure on a PTP Port (see Annex G). This data set is used instead of the cmldsAsymmetryMeasurementModeDS, when only domain 0 is present and CMLDS is not used."
],
null,
null,
[
"INDEX",
[
[
0,
"ieee8021AsV3PtpInstance"
],
[
0,
"ieee8021AsV3AsymMeasurementModeDSAsIndex"
]
]
],
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V3-MIB::ieee8021AsV3AsymMeasurementModeDSEntry.Source version and references
Downloaded: 2026-10-19T00:21:26.981307+00:00. SHA-256:
7ff3709990346689da5c9cbfffabf2529ce6183419a2c83fb38574811a42106e{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V3-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV3AsymMeasurementModeDSEntry OBJECT-TYPE\r\n SYNTAX Ieee8021AsV3AsymMeasurementModeDSEntry\r\n MAX-ACCESS not-accessible\r\n STATUS current\r\n DESCRIPTION\r\n "The asymmetryMeasurementModeDS represents the capability to\r\n enable/disable the Asymmetry Compensation Measurement Procedure\r\n on a PTP Port (see Annex G). This data set is used instead of\r\n the cmldsAsymmetryMeasurementModeDS, when only domain 0 is\r\n present and CMLDS is not used. "\r\n INDEX { ieee8021AsV3PtpInstance,\r\n ieee8021AsV3AsymMeasurementModeDSAsIndex }\r\n ::= { ieee8021AsV3AsymMeasurementModeDSTable 1 }', 'syntax_tree': [['row', 'Ieee8021AsV3AsymMeasurementModeDSEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The asymmetryMeasurementModeDS represents the capability to enable/disable the Asymmetry Compensation Measurement Procedure on a PTP Port (see Annex G). This data set is used instead of the cmldsAsymmetryMeasurementModeDS, when only domain 0 is present and CMLDS is not used.'], None, None, ['INDEX', [[0, 'ieee8021AsV3PtpInstance'], [0, 'ieee8021AsV3AsymMeasurementModeDSAsIndex']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}