The value is equal to the value of the Boolean asymmetryMeasurementMode. For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this PTP Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2). Setting this managed object causes the Boolean asymmetryMeasurementMode to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the PTP Ports at each end of the link.
Status in source: current.
Names: ieee8021AsV3AsymMeasurementModeDSAsymMeasurementMode
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021AsV3AsymMeasurementModeDSAsymMeasurementMode",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value is equal to the value of the Boolean asymmetryMeasurementMode. For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this PTP Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2). Setting this managed object causes the Boolean asymmetryMeasurementMode to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the PTP Ports at each end of the link.\"",
"REFERENCE",
"\"14.15.2\"",
"::=",
"{",
"ieee8021AsV3AsymMeasurementModeDSEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value is equal to the value of the Boolean asymmetryMeasurementMode. For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this PTP Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2). Setting this managed object causes the Boolean asymmetryMeasurementMode to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the PTP Ports at each end of the link."
],
[
"REFERENCE",
"14.15.2"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-AS-V3-MIB::ieee8021AsV3AsymMeasurementModeDSAsymMeasurementMode.Source version and references
Downloaded: 2026-10-19T00:21:26.981307+00:00. SHA-256:
7ff3709990346689da5c9cbfffabf2529ce6183419a2c83fb38574811a42106e{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-AS-V3-MIB', 'imports': {'IF-MIB': ['InterfaceIndexOrZero'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'FLOAT-TC-MIB': ['Float64TC'], 'IEEE8021-TC-MIB': ['IEEE8021BridgePortNumber'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021AsV3AsymMeasurementModeDSAsymMeasurementMode OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-write\r\n STATUS current\r\n DESCRIPTION\r\n "The value is equal to the value of the Boolean\r\n asymmetryMeasurementMode. For full-duplex IEEE 802.3\r\n media, the value is TRUE (1) if an asymmetry measurement\r\n is being performed for the link attached to this PTP Port,\r\n and FALSE (2) otherwise. For all other media, the value\r\n shall be FALSE (2). Setting this managed object causes the\r\n Boolean asymmetryMeasurementMode to have the same value.\r\n NOTE: If an asymmetry measurement is being performed for a\r\n link, asymmetryMeasurementMode must be TRUE (1) for the\r\n PTP Ports at each end of the link."\r\n REFERENCE "14.15.2"\r\n ::= { ieee8021AsV3AsymMeasurementModeDSEntry 2 }', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-write'], ['Status', 'current'], ['DESCRIPTION', 'The value is equal to the value of the Boolean asymmetryMeasurementMode. For full-duplex IEEE 802.3 media, the value is TRUE (1) if an asymmetry measurement is being performed for the link attached to this PTP Port, and FALSE (2) otherwise. For all other media, the value shall be FALSE (2). Setting this managed object causes the Boolean asymmetryMeasurementMode to have the same value. NOTE: If an asymmetry measurement is being performed for a link, asymmetryMeasurementMode must be TRUE (1) for the PTP Ports at each end of the link.'], ['REFERENCE', '14.15.2'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}