OID reference

vdslPhysEntry

1.3.6.1.2.1.10.97.1.1.2.1

Description

An entry in the vdslPhysTable.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.2.1.10.97.1.1.2 (vdslPhysTable)
Node code
1
Node name
vdslPhysEntry
Category
SNMP management object
Numeric OID
1.3.6.1.2.1.10.97.1.1.2.1
URN notation
urn:oid:1.3.6.1.2.1.10.97.1.1.2.1
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 2 1 10 97 1 1 2 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) mgmt(2) stdmib-2(1) transmission(10) vdslMIB(97) vdslLineMib(1) vdslMibObjects(1) vdslPhysTable(2) vdslPhysEntry(1)}
OID-IRI notation
  • /1/3/6/1/2/1/10/97/1/1/2/1
  • /ISO/Identified-Organization/6/1/2/1/10/97/1/1/2/1
  • /ISO/3/6/1/2/1/10/97/1/1/2/1
Named path variants
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/identified-organization/dod/internet/mgmt/stdmib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/org/dod/internet/mgmt/mib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/org/dod/internet/mgmt/mib/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/org/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/org/dod/internet/mgmt/stdmib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-identified-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-identified-organization/dod/internet/mgmt/stdmib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-organization/dod/internet/mgmt/mib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-organization/dod/internet/mgmt/mib/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-organization/dod/internet/mgmt/RFC1066-MIB-INTERPRETATION/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry
  • /iso/iso-organization/dod/internet/mgmt/stdmib-2/transmission/vdslMIB/vdslLineMib/vdslMibObjects/vdslPhysTable/vdslPhysEntry

SNMP properties

Value type
VdslPhysEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

An entry in the vdslPhysTable.
Original text from OID Repository
vdslPhysEntry OBJECT-TYPE
SYNTAX VdslPhysEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the vdslPhysTable."
INDEX { ifIndex,
vdslPhysSide }
Sources for this description

OID Repository

View at oid-base.com
Automatically extracted from RFC3728

Circitor

Parsed from VDSL-LINE-MIB.mib · VDSL-LINE-MIB

Source file: Download VDSL-LINE-MIB.txt · Publisher's file

Vendor MIB copy from the Netdisco archive.

Source file: Download VDSL-LINE-MIB · Publisher's file

Vendor MIB copy from the LibreNMS archive.

Source file: Download VDSL-LINE-MIB · Publisher's file

Vendor MIB copy from the Observium Community archive.

Related source files and packages:

Source file: Download RFC 3728 · Publisher's file · RFC errata

Source file: Download VDSL-LINE-MIB.mib

Browse all files from Circitor

Historical records

Additional source information

Information from MIBdepot
vdslPhysEntry OBJECT-TYPE
       SYNTAX       VdslPhysEntry
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION  "An entry in the vdslPhysTable."
       INDEX { ifIndex,
               vdslPhysSide }
       ::= { vdslPhysTable 1 }
Information from Circitor
vdslPhysEntry OBJECT-TYPE
    SYNTAX       VdslPhysEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION  "An entry in the vdslPhysTable."
    INDEX { ifIndex,
            vdslPhysSide }
    ::= { vdslPhysTable 1 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6)

Defense Communication Agency

Current Registration Authority (inferred from ancestor 1.3.6.1.2)

Internet Assigned Numbers Authority

Direct children (10)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.2.1.10.97.1.1.2.1.1 vdslPhysSide00 Identifies whether the transceiver is the Vtuc or Vtur.
1.3.6.1.2.1.10.97.1.1.2.1.2 vdslPhysInvSerialNumber00 The vendor specific string that identifies the



vendor equipment.
1.3.6.1.2.1.10.97.1.1.2.1.3 vdslPhysInvVendorID00 The vendor ID code is a copy of the binary vendor
identification field expressed as readable characters
in hexadecimal notation.
1.3.6.1.2.1.10.97.1.1.2.1.4 vdslPhysInvVersionNumber00 The vendor specific version number sent by this Vtu
as part of the initialization messages. It is a copy
of the binary version n…
1.3.6.1.2.1.10.97.1.1.2.1.5 vdslPhysCurrSnrMgn00 Noise Margin as seen by this Vtu with respect to its
received signal in 0.25dB. The effective range is
-31.75 to +31.75 dB.
1.3.6.1.2.1.10.97.1.1.2.1.6 vdslPhysCurrAtn00 Measured difference in the total power transmitted by
the peer Vtu and the total power received by this Vtu.
The effective range …
1.3.6.1.2.1.10.97.1.1.2.1.7 vdslPhysCurrStatus00 Indicates current state of the Vtu line. This is a
bit-map of possible conditions. The various bit
positions are:

0 noDefect …
1.3.6.1.2.1.10.97.1.1.2.1.8 vdslPhysCurrOutputPwr00 Measured total output power transmitted by this VTU.
This is the measurement that was reported during
the last activation sequenc…
1.3.6.1.2.1.10.97.1.1.2.1.9 vdslPhysCurrAttainableRate00 Indicates the maximum currently attainable data rate
in steps of 1000 bits/second by the Vtu. This value
will be equal to or gre…
1.3.6.1.2.1.10.97.1.1.2.1.10 vdslPhysCurrLineRate00 Indicates the current data rate in steps of 1000
bits/second by the Vtu. This value will be less than
or equal to vdslPhysCurrAt…