Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is in the state POWER_ON for a duration greater than
tlim max (see IEEE Std 802.3af Table 33-5 tlim).
A value of fault(4) - indicates that the PSE State diagram is
in the state TEST_ERROR.
A value of test(5) - indicates that the PSE State diagram is
in the state TEST_MODE.
A value of otherFault(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
A value of searching(2)- indicates the PSE State diagram is
in a state other than those listed above.
pethPsePortDetectionStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
searching(2),
deliveringPower(3),
fault(4),
test(5),
otherFault(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is in the state POWER_ON for a duration greater than
tlim max (see IEEE Std 802.3af Table 33-5 tlim).
A value of fault(4) - indicates that the PSE State diagram is
in the state TEST_ERROR.
A value of test(5) - indicates that the PSE State diagram is
in the state TEST_MODE.
A value of otherFault(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
A value of searching(2)- indicates the PSE State diagram is
in a state other than those listed above."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.5
aPSEPowerDetectionStatus"
View at oid-info.com
Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is in the state POWER_ON for a duration greater than
tlim max (see IEEE Std 802.3af Table 33-5 tlim).
A value of fault(4) - indicates that the PSE State diagram is
in the state TEST_ERROR.
A value of test(5) - indicates that the PSE State diagram is
in the state TEST_MODE.
A value of otherFault(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
A value of searching(2)- indicates the PSE State diagram is
in a state other than those listed above.
pethPsePortDetectionStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of deliveringPower(3) - indicates that the PSE State diagram is in the state POWER_ON for a duration greater than tlim max (see IEEE Std 802.3af Table 33-5 tlim). A value of fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR. A value of test(5) - indicates that the PSE State diagram is in the state TEST_MODE. A value of otherFault(6) - indicates that the PSE State diagram is in the state IDLE due to the variable error_conditions. A value of searching(2)- indicates the PSE State diagram is in a state other than those listed above." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.5 aPSEPowerDetectionStatus" ::= { pethPsePortEntry 6 }
Automatically extracted from RFC3621
pethPsePortDetectionStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of deliveringPower(3) - indicates that the PSE State diagram is in the state POWER_ON for a duration greater than tlim max (see IEEE Std 802.3af Table 33-5 tlim). A value of fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR. A value of test(5) - indicates that the PSE State diagram is in the state TEST_MODE. A value of otherFault(6) - indicates that the PSE State diagram is in the state IDLE due to the variable error_conditions. A value of searching(2)- indicates the PSE State diagram is in a state other than those listed above." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.5 aPSEPowerDetectionStatus" ::= { pethPsePortEntry 6 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.105.1.1.1.1 | pethPsePortGroupIndex | 0 | 0 | This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in t… |
1.3.6.1.2.1.105.1.1.1.2 | pethPsePortIndex | 0 | 0 | This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE … |
1.3.6.1.2.1.105.1.1.1.3 | pethPsePortAdminEnable | 0 | 0 | true (1) An interface which can provide the PSE functions. false(2) The interface will act as it would if it had no PSE function. |
1.3.6.1.2.1.105.1.1.1.4 | pethPsePortPowerPairsControlAbility | 0 | 0 | Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate … |
1.3.6.1.2.1.105.1.1.1.5 | pethPsePortPowerPairs | 0 | 0 | Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of… |
1.3.6.1.2.1.105.1.1.1.7 | pethPsePortPowerPriority | 0 | 0 | This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set b… |
1.3.6.1.2.1.105.1.1.1.8 | pethPsePortMPSAbsentCounter | 0 | 0 | This counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpd… |
1.3.6.1.2.1.105.1.1.1.9 | pethPsePortType | 0 | 0 | A manager will set the value of this variable to indicate the type of powered device that is connected to the port. The default v… |
1.3.6.1.2.1.105.1.1.1.10 | pethPsePortPowerClassifications | 0 | 0 | Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices su… |
1.3.6.1.2.1.105.1.1.1.11 | pethPsePortInvalidSignatureCounter | 0 | 0 | This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID. |
1.3.6.1.2.1.105.1.1.1.12 | pethPsePortPowerDeniedCounter | 0 | 0 | This counter is incremented when the PSE state diagram enters the state POWER_DENIED. |
1.3.6.1.2.1.105.1.1.1.13 | pethPsePortOverLoadCounter | 0 | 0 | This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER. |
1.3.6.1.2.1.105.1.1.1.14 | pethPsePortShortCounter | 0 | 0 | This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_SHORT. |