rohcRtpContextPktsLostPhysical OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is only applicable to decompressor contexts
using the LLA profile. It contains the number of physical
packet losses on the link between compressor and
decompressor, that have been indicated to the decompressor.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable of the ROHC-MIB.
The value of this object is only valid for LLA profiles,
i.e., if the corresponding rohcProfile has a value of
0x0005. If the corresponding rohcProfile has a value
other than 0x0005, then this object MUST NOT be
instantiated."
REFERENCE
"RFC 3242, Section 5.1.2."
View at oid-info.com
This object is only applicable to decompressor contexts
using the LLA profile. It contains the number of physical
packet losses on the link between compressor and
decompressor, that have been indicated to the decompressor.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable of the ROHC-MIB.
The value of this object is only valid for LLA profiles,
i.e., if the corresponding rohcProfile has a value of
0x0005. If the corresponding rohcProfile has a value
other than 0x0005, then this object MUST NOT be
instantiated.
Parsed from file rfc3816-RObust-Header-Compression-ROHC.mib-3.txt
Company: None
Module: ROHC-RTP-MIB
This object is only applicable to decompressor contexts
using the LLA profile. It contains the number of physical
packet losses on the link between compressor and
decompressor, that have been indicated to the decompressor.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable of the ROHC-MIB.
The value of this object is only valid for LLA profiles,
i.e., if the corresponding rohcProfile has a value of
0x0005. If the corresponding rohcProfile has a value
other than 0x0005, then this object MUST NOT be
instantiated.
Parsed from file ROHC-RTP-MIB.mib
Module: ROHC-RTP-MIB
Automatically extracted from RFC3816
rohcRtpContextPktsLostPhysical OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to decompressor contexts using the LLA profile. It contains the number of physical packet losses on the link between compressor and decompressor, that have been indicated to the decompressor. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.2." ::= { rohcRtpContextEntry 16 }
rohcRtpContextPktsLostPhysical OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is only applicable to decompressor contexts using the LLA profile. It contains the number of physical packet losses on the link between compressor and decompressor, that have been indicated to the decompressor. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. For checking ifCounterDiscontinuityTime, the interface index is required. It can be determined by reading the rohcChannelTable of the ROHC-MIB. The value of this object is only valid for LLA profiles, i.e., if the corresponding rohcProfile has a value of 0x0005. If the corresponding rohcProfile has a value other than 0x0005, then this object MUST NOT be instantiated." REFERENCE "RFC 3242, Section 5.1.2." ::= { rohcRtpContextEntry 16 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.114.1.1.1.3 | rohcRtpContextState | 0 | 0 | State of the context as defined in RFC 3095. States initAndRefresh(1), firstOrder(2), and secondOrder(3) are states of compresso… |
1.3.6.1.2.1.114.1.1.1.4 | rohcRtpContextMode | 0 | 0 | Mode of the context. |
1.3.6.1.2.1.114.1.1.1.5 | rohcRtpContextAlwaysPad | 0 | 0 | Boolean, only applicable to compressor contexts using the LLA profile. If its value is true, the compressor must pad every RHP p… |
1.3.6.1.2.1.114.1.1.1.6 | rohcRtpContextLargePktsAllowed | 0 | 0 | Boolean, only applicable to compressor contexts using the LLA profile. It specifies how to handle packets that do not fit any of… |
1.3.6.1.2.1.114.1.1.1.7 | rohcRtpContextVerifyPeriod | 0 | 0 | This object is only applicable to compressor contexts using the LLA profile. It specifies the minimum frequency with which a pac… |
1.3.6.1.2.1.114.1.1.1.8 | rohcRtpContextSizesAllowed | 0 | 0 | The value of this object is only valid for decompressor contexts, i.e., if rohcInstanceType of the corresponding rohcContextEntry… |
1.3.6.1.2.1.114.1.1.1.9 | rohcRtpContextSizesUsed | 0 | 0 | The value of this object is only valid for decompressor contexts, i.e., if rohcInstanceType of the corresponding rohcContextEntry… |
1.3.6.1.2.1.114.1.1.1.10 | rohcRtpContextACKs | 0 | 0 | The number of all positive feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value of this c… |
1.3.6.1.2.1.114.1.1.1.11 | rohcRtpContextNACKs | 0 | 0 | The number of all dynamic negative feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value o… |
1.3.6.1.2.1.114.1.1.1.12 | rohcRtpContextSNACKs | 0 | 0 | The number of all static negative feedbacks (ACK) sent or received in this context, respectively. Discontinuities in the value of… |
1.3.6.1.2.1.114.1.1.1.13 | rohcRtpContextNHPs | 0 | 0 | This object is only applicable to contexts using the LLA profile. It contains the number of all no-header packets (NHP) sent or … |
1.3.6.1.2.1.114.1.1.1.14 | rohcRtpContextCSPs | 0 | 0 | This object is only applicable to contexts using the LLA profile. It contains the number of all context synchronization packets … |
1.3.6.1.2.1.114.1.1.1.15 | rohcRtpContextCCPs | 0 | 0 | This object is only applicable to contexts using the LLA profile. It contains the number of all context check packets (CCP) sent… |
1.3.6.1.2.1.114.1.1.1.17 | rohcRtpContextPktsLostPreLink | 0 | 0 | This object is only applicable to decompressor contexts using the LLA profile. It contains the number of pre-link packet losses … |