arcTable OBJECT-TYPE
SYNTAX SEQUENCE OF ArcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Alarm Reporting Control (ARC) settings on the system.
Alarm Reporting Control is a feature that provides an automatic
in-service provisioning capability. Alarm reporting is turned
off on a per-resource basis for a selective set of potential
alarm conditions to allow sufficient time for customer testing
and other maintenance activities in an alarm free state.
Once a resource is ready for service, alarm reporting is
automatically or manually turned on.
Functional description and requirements of Alarm Reporting
Control are defined in Recommendation ITU-T M.3100 Amendment 3
[M.3100 Amd3]."
REFERENCE
"ITU Recommendation M.3100 Amendment 3, Generic Network
Information Model, January 2001."
View at oid-info.com
A table of Alarm Reporting Control (ARC) settings on the system.
Alarm Reporting Control is a feature that provides an automatic
in-service provisioning capability. Alarm reporting is turned
off on a per-resource basis for a selective set of potential
alarm conditions to allow sufficient time for customer testing
and other maintenance activities in an 'alarm free' state.
Once a resource is ready for service, alarm reporting is
automatically or manually turned on.
Functional description and requirements of Alarm Reporting
Control are defined in ITU-T Recommendation M.3100 Amendment 3
[M.3100 Amd3].
Parsed from file ARC-MIB.mib
Module: ARC-MIB
Automatically extracted from RFC3878
arcTable OBJECT-TYPE SYNTAX SEQUENCE OF ArcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Alarm Reporting Control (ARC) settings on the system. Alarm Reporting Control is a feature that provides an automatic in-service provisioning capability. Alarm reporting is turned off on a per-resource basis for a selective set of potential alarm conditions to allow sufficient time for customer testing and other maintenance activities in an 'alarm free' state. Once a resource is ready for service, alarm reporting is automatically or manually turned on. Functional description and requirements of Alarm Reporting Control are defined in ITU-T Recommendation M.3100 Amendment 3 [M.3100 Amd3]." REFERENCE "ITU Recommendation M.3100 Amendment 3, 'Generic Network Information Model', January 2001." ::= { arcObjects 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.117.2.1.1 | arcEntry | 7 | 7 | A conceptual row that contains information about an ARC setting of a resource in the system. Implementation need to be aware that… |