An instance of the alarm indicated by
alarmActiveModelPointer has been raised
against the entity indicated by
alarmActiveResourceId.
The agent must throttle the generation of
consecutive alarmActiveState traps so that there is at
least a two-second gap between traps of this
type against the same alarmActiveModelPointer and
alarmActiveResourceId. When traps are throttled,
they are dropped, not queued for sending at a future time.
A management application should periodically check
the value of alarmActiveLastChanged to detect any
missed alarmActiveState notification-events, e.g.,
due to throttling or transmission loss.
Parsed from file Alarm.mib.txt
Company: None
Module: ALARM-MIB
Automatically extracted from RFC3877
alarmActiveState NOTIFICATION-TYPE OBJECTS { alarmActiveModelPointer, alarmActiveResourceId } STATUS current DESCRIPTION "An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId. The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are dropped, not queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss." ::= { alarmNotifications 2 }
alarmGroups OBJECT IDENTIFIER ::= { alarmConformance 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.118.2.2.1 | alarmModelGroup | 0 | 0 | Alarm model group. |
1.3.6.1.2.1.118.2.2.2 | alarmActiveGroup | 0 | 0 | Active Alarm list group. |
1.3.6.1.2.1.118.2.2.3 | alarmActiveStatsGroup | 0 | 0 | Active alarm summary group. |
1.3.6.1.2.1.118.2.2.4 | alarmClearGroup | 0 | 0 | Cleared alarm group. |
1.3.6.1.2.1.118.2.2.6 | alarmNotificationsGroup | 0 | 0 | The collection of notifications that can be used to model alarms for faults lacking pre-existing notification definitions. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.118.2.0 | 2 | 2 | None | |
1.3.6.1.2.1.118.2.1 | alarmCompliances | 1 | 1 | None |
1.3.6.1.2.1.118.2.3 | alarmClearState | 0 | 0 | An instance of the alarm indicated by alarmActiveModelPointer has been cleared against the entity indicated by alarmActiveResourc… |