teModuleServerReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "When this MIB module is implemented by a path
computation server without support for read-create
(i.e., in read-only mode), then the implementation
can claim read-only compliance. Such
a device can be monitored but cannot be
configured with this MIB module.
"
MODULE -- enclosing module, i.e., TE-MIB
MANDATORY-GROUPS {
teTrafficEngineeringGroup
}
GROUP teNotificationGroup
DESCRIPTION "Implementation of this group is optional."
OBJECT teNotificationEnable
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teAdminGroupRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelSourceAddressType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required. A path
computation server SHOULD implement all types
of tunnel source address types.
"
OBJECT teTunnelSourceAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddressType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT teTunnelDestinationAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathName
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathtype
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathConfiguredRoute
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathBandwidth
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAny
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathIncludeAll
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathExclude
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathSetupPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHoldPriority
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathProperties
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathAdminStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopStorageType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddrType
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
OBJECT tePathHopAddress
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
View at oid-info.com
When this MIB module is implemented by a path
computation server without support for read-create
(i.e., in read-only mode), then the implementation
can claim read-only compliance. Such
a device can be monitored but cannot be
configured with this MIB module.
Parsed from file rfc3970-Traffic-Engineering-TE.mib.txt
Company: None
Module: TE-MIB
When this MIB module is implemented by a path
computation server without support for read-create
(i.e., in read-only mode), then the implementation
can claim read-only compliance. Such
a device can be monitored but cannot be
configured with this MIB module.
Parsed from file TE-MIB.mib
Module: TE-MIB
Automatically extracted from RFC3970
teModuleServerReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB module is implemented by a path computation server without support for read-create (i.e., in read-only mode), then the implementation can claim read-only compliance. Such a device can be monitored but cannot be configured with this MIB module. " MODULE MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teNotificationEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelSourceAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required. A path computation server SHOULD implement all types of tunnel source address types. " OBJECT teTunnelSourceAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathConfiguredRoute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathBandwidth MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAny MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAll MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathExclude MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathSetupPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHoldPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathProperties MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddrType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { teModuleCompliance 3 }
teModuleServerReadOnlyCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "When this MIB module is implemented by a path computation server without support for read-create (i.e., in read-only mode), then the implementation can claim read-only compliance. Such a device can be monitored but cannot be configured with this MIB module. " MODULE MANDATORY-GROUPS { teTrafficEngineeringGroup } GROUP teNotificationGroup DESCRIPTION "Implementation of this group is optional." OBJECT teNotificationEnable MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teAdminGroupRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelSourceAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required. A path computation server SHOULD implement all types of tunnel source address types. " OBJECT teTunnelSourceAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddressType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT teTunnelDestinationAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathName MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathConfiguredRoute MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathBandwidth MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAny MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathIncludeAll MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathExclude MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathSetupPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHoldPriority MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathProperties MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopRowStatus SYNTAX RowStatus { active(1) } MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopStorageType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddrType MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT tePathHopAddress MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { teModuleCompliance 3 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.122.2.2.1 | teModuleReadOnlyCompliance | 0 | 0 | When this MIB module is implemented without support for read-create (i.e., in read-only mode), then such an implementation can cl… |
1.3.6.1.2.1.122.2.2.2 | teModuleFullCompliance | 0 | 0 | When this MIB module is implemented with support for read-create, then the implementation can claim full compliance. Such device… |
1.3.6.1.2.1.122.2.2.4 | teModuleServerFullCompliance | 0 | 0 | When this MIB module is implemented by a path computation server with support for read-create, then the implementation can claim … |