meters, as perceived by the PME after the link is established.
An equivalent loop is a hypothetical 26AWG (0.4mm) loop with a
perfect square root attenuation characteristic, without any
bridged taps.
The value of 65535 is returned if the link is Down or
Initializing or the PME is unable to estimate the equivalent
length.
For a 10BASE-TL PME, if a Clause 45 MDIO Interface to the PME
is present, then this object maps to the 10P Electrical Length
register.
Sources for this description
Circitor
Parsed from EFM-CU-MIB.mib · EFM-CU-MIB
Source file: Download EFM-CU-MIB.txt · Publisher's file
Vendor MIB copy from the Netdisco archive.
Related source files and packages:
Source file: Download EFM-CU-MIB · Publisher's file
Vendor MIB copy from the Observium Community archive.
Related source files and packages:
Source file: Download RFC 5066 · Publisher's file · RFC errata
Source file: Download EFM-CU-MIB.mib