upsTestElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time, in TimeTicks, since the test in
progress was initiated, or, if no test is in progress,
the previous test took to complete. If the value of
upsTestResultsSummary is noTestsInitiated(6),
upsTestElapsedTime has the value 0."
View at oid-info.com
The amount of time, in TimeTicks, since the test in
progress was initiated, or, if no test is in progress,
the previous test took to complete. If the value of
upsTestResultsSummary is noTestsInitiated(6),
upsTestElapsedTime has the value 0.
Parsed from file UPS.mib.txt
Company: None
Module: UPS-MIB
The amount of time, in TimeTicks, since the test in
progress was initiated, or, if no test is in progress,
the previous test took to complete. If the value of
upsTestResultsSummary is noTestsInitiated(6),
upsTestElapsedTime has the value 0.
Parsed from file UPS-MIB.mib
Module: UPS-MIB
Automatically extracted from RFC1628
upsTestElapsedTime OBJECT-TYPE SYNTAX TimeInterval ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0." ::= { upsTest 6 }
upsTestElapsedTime OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0." ::= { upsTest 6 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.33.1.7.6.0 | upsTestElapsedTime | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.33.1.7.1 | upsTestId | 1 | 1 | The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known… |
1.3.6.1.2.1.33.1.7.2 | upsTestSpinLock | 1 | 1 | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure th… |
1.3.6.1.2.1.33.1.7.3 | upsTestResultsSummary | 1 | 1 | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) … |
1.3.6.1.2.1.33.1.7.4 | upsTestResultsDetail | 1 | 1 | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned. |
1.3.6.1.2.1.33.1.7.5 | upsTestStartTime | 1 | 1 | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test … |
1.3.6.1.2.1.33.1.7.7 | upsWellKnownTests | 5 | 10 | None |